Key points
From the paper's conclusion- The compressive behavior of desert sand-fly ash cenosphere lightweight aggregate concrete (DFCC) under steel tube confinement differs from that of conventional lightweight aggregate concrete, and existing constitutive models may not adequately characterize its stress-strain response.
Abstract
The compressive behavior of desert sand-fly ash cenosphere lightweight aggregate concrete (DFCC) under steel tube confinement differs from that of conventional lightweight aggregate concrete, and existing constitutive models may not adequately characterize its stress-strain response. This study aims to develop a compressive constitutive model for DFCC under steel tube confinement and evaluate its applicability to the axial response analysis of DFCC-filled steel tube stub columns. Uniaxial compression tests were first conducted to characterize the complete stress-strain response of unconfined DFCC, followed by finite element analyses of DFCC under different levels of steel tube confinement. Axial compression tests and numerical simulations of five DFCC-filled steel tube stub columns were further used for component-level evaluation. The results showed that unconfined DFCC exhibited pronounced post-peak softening, and the Hu model reproduced the measured complete stress-strain curves with coefficients of determination ranging from 0.9646 to 0.9794. Steel tube confinement enhanced the compressive resistance, deformation capacity, and post-peak residual strength of DFCC. Based on the confined stress-strain responses, a modified constitutive model was established by recalibrating the peak parameters and post-peak branch. When implemented in the finite element analysis of the stub columns, the ratios of experimental to numerical ultimate loads ranged from 0.97 to 1.06, with a mean value of 1.02 and a standard deviation of 0.035. The proposed model can therefore provide a practical constitutive description for the axial analysis of DFCC under steel tube confinement within the investigated parameter range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Confinement on Sustainable Concrete-Filled Steel Tubular Stub Columns Incorporating Recycled Waste MaterialsBuildings · 2026
- A novel FRP–steel–UHPC composite column system for marine structures: Axial compressive behavior and analytical modelStructural Concrete · 2026
- Experimental study on the axial behavior of steel slag fine aggregate concrete stub columnsStructural Concrete · 2026
- Axial compression behavior of hybrid fiber reinforced concrete encased cold‐formed steel composite columns: An experimental and theoretical investigationStructural Concrete · 2026
- FRP–Steel Composite Tube Confined Seawater–Sea-Sand Concrete Columns: State-of-the-Art ReviewBuildings · 2026
- Study on Multi-Component Modification and Performance Optimization of High-Salt Mine Water Mixed and Sprayed Concrete Based on Response Surface Methodology.Materials (Basel, Switzerland) · 2026