Reliable Atom Probe Quantification of Carbon in Non-Stoichiometric TiCx: Effects of Laser Energy and Correction of Carbon Loss.
Yibing Xie, Haokai Su, Bing Hu, Shenbao Jin
School of Materials Science and Engineering, Hebei University of Technology, Tianjin 300401, China. · School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Key points
From the paper's conclusion- Therefore, among the investigated conditions, 40 pJ is preferable for reliable APT carbon quantification in TiCx.
Abstract
Accurate carbon quantification in TiCx by atom probe tomography (APT) is strongly affected by the evaporation of carbon-containing molecular ions, detector dead time and peak overlap. Here, APT mass spectra, hit multiplicity and correlation histograms acquired at 40-400 pJ were analyzed to characterize laser-energy-dependent evaporation. With increasing laser energy, carbon shifted toward C2+-C5+ molecular ions and Ti-C complexes, including TiC+, TiC2+-TiC5+ and Ti2C22+. The fraction of detected carbon carried by molecular ions increased from 47% to 98%, while the uncorrected C/Ti ratio decreased from 0.52 to 0.26. Multiplicity and correlation analyses indicated that carbon-rich molecular ions were susceptible to incomplete registration within the detector dead time. After correction for dead-time-related losses of C2+ and C+ at 6 and 12 Da as well as for the 24 Da overlap between 48Ti2+ and C2+, the C/Ti ratio increased to 0.92 at 40 pJ and 0.83 at 60 pJ, approaching the XRD-derived range of 0.85-0.95. At higher energies, the correction remained insufficient because the method does not explicitly account for C3+-C5+ molecular-ion losses, whose broad peaks and unresolved minor-isotope peaks prevent reliable isotope-based correction. Therefore, among the investigated conditions, 40 pJ is preferable for reliable APT carbon quantification in TiCx.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Using Detection Efficiency as an Indicator of Losses During Atom Probe Tomography Analysis of Oxygen-Rich Materials.Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada · 2026
- Exploring Mechanisms Leading to Composition Errors in Monazite (CePO4) Analyzed With Atom Probe TomographyMicroscopy and Microanalysis · 2026
- Numerical modelling of laser absorption and heat transport in metallic-overcoated APT specimens.Ultramicroscopy · 2026
- Correlation Between Dopant Atom Evaporation Field and Measured Site Preference in Atom Probe TomographyarXiv · 2026
- MicroCup: A Cryogenic Specimen Preparation Strategy for Atom Probe Tomography of Organic Molecular Liquids.Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada · 2026
- Nanoscale identification of organic pigments in biogenic calcite by atom probe tomographybioRxiv · 2026