Bulk Phase Proportion Governs the Wear Performance of PEO Coatings Grown on Biomedical Ti-6Al-4V Alloy.
José Roberto Ferreira Neto, Jhuliene Elen Muro Torrento, Carlos Eduardo da Silva, Fernanda de Freitas Quadros, Carlos Roberto Grandini, Sophia Alexandra Tsipas, Diego Rafael Nespeque Correa
Laboratory of Anelasticity and Biomaterials, School of Sciences, São Paulo State University (UNESP), Campus Bauru, Bauru 17033-360, SP, Brazil. · Department of Materials Science and Engineering and Chemical Engineering, University Carlos III of Madrid, IAAB, Avda. de la Universidad, 30, 28911 Leganés, Spain.
Key points
From the paper's conclusion- These findings highlight that tailoring the α/β ratio through heat treatment combined with PEO treatment enhances wear performance, offering promising implications for clinical translation in biomedical implants.
Abstract
This study investigated the combined influence of the α/β phase proportion and Plasma Electrolytic Oxidation (PEO) on the wear behavior of Ti-6Al-4V alloy. Samples with distinct α/β phase ratios induced by previous heat treatments (600, 800, and 1000 °C) were subjected to dry sliding wear tests before and after PEO treatment. The untreated samples exhibited major abrasive and minor adhesive wear mechanisms, characterized by broad scratches and minor adhered debris. In contrast, PEO-treated samples exhibited predominant adhesive wear, indicating a significant tuning in the wear mechanism. The coefficient of friction (COF) was unaffected by phase proportions in untreated samples but was influenced by PEO treatment. Volume loss and wear rate were sensitive to phase composition, with the untreated samples heat-treated above 800 °C exhibiting the highest values, likely due to the retention of the metastable α' phase. Conversely, PEO-treated samples demonstrated markedly reduced wear, confirming the protective role of the oxide layer. Energy-dispersive spectroscopy (EDS) revealed the counterbody's particle adhesion in untreated tracks, whereas PEO-treated tracks retained the coating, evidencing superior wear resistance. These findings highlight that tailoring the α/β ratio through heat treatment combined with PEO treatment enhances wear performance, offering promising implications for clinical translation in biomedical implants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tungsten Oxide-contained PEO Coatings on Ti-6Al‑4 V Alloys: Enhanced Surface Characteristics and Bioactivity for Bio-implant.ACS omega · 2026
- Surface modification of titanium alloys and its effects on corrosion resistance and cell responseJournal of Materials Research and Technology · 2026
- Fretting Wear Resistance of Si(C, N) Coatings Deposited on the Surface of Dental AlloysCoatings · 2026
- Effect of Surface Treatment on Microstructure and Tribological Behavior of Ti–4Al–2.5V–1.2Fe Alloy Drill Pipe Using Micro-Arc Oxidation, Anodic Oxidation and Laser CladdingProcesses · 2026
- Biofunctionalization of SLM Ti–40Nb alloy through hydroxyapatite-modified plasma electrolytic oxidation coatingApplied Surface Science Advances · 2025
- Enhanced of friction and wear properties for TiC/TC4 coating based on the precipitation of the lubricating and strengthening phases through laser cladding of Cr–WS2–Ni60 powderJournal of Materials Research and Technology · 2025