Thermoelastic State of a Magnetocaloric Ferromagnetic Plate Under Constant-Rate Ambient Temperature Rise.
Roman Musii, Myroslava Klapchuk, Uliana Zhydyk, Nelya Pabyrivska, Zenoviy Kohut, Dariusz Całus, Piotr Gębara, Karolina Kutynia
Institute of Applied Mathematics and Fundamental Sciences, Lviv Polytechnic National University, 79013 Lviv, Ukraine. · Faculty of Electrical Engineering, Czestochowa University of Technology, 42-200 Czestochowa, Poland.
Key points
From the paper's conclusion- The results obtained provide a quantitative basis for assessing the thermoelastic state and for optimizing the geometry and operating conditions of active magnetic regenerator plate stacks with a view to enhancing their structural reliability.
Abstract
A simply supported rectangular isotropic ferromagnetic plate with magnetocaloric properties subjected to convective heating on its upper surface is considered. The governing equations comprise a system of two-dimensional transient equations for the thickness-averaged temperature characteristics of the plate and the two-dimensional bending equations for isotropic plates expressed in terms of generalized displacements within the framework of first-order shear deformation theory. Closed-form solutions to the governing equations are obtained by expanding all thermal and mechanical field quantities in double Fourier sine series satisfying the prescribed boundary conditions, combined with the Laplace transform in time applied to the thermal quantities. A comparative numerical analysis is carried out for the magnetocaloric ferromagnetic plate and a carbon steel plate under ambient temperature rising at a finite rate to a prescribed value. The dependences of all quantities under investigation on the ambient temperature rise rate, time, convective heat transfer coefficient, thermal conductivity of the ferromagnetic material, and geometric parameters of the plate are analyzed and presented graphically. The results obtained provide a quantitative basis for assessing the thermoelastic state and for optimizing the geometry and operating conditions of active magnetic regenerator plate stacks with a view to enhancing their structural reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Melting Heat Transfer in Ferromagnetic Carreau Fluid Flow Under a Magnetic Dipole: Critical Eckert Number and Entropy GenerationProcesses · 2026
- Thermal management of magneto-ferrofluid operated circular thermal systems with thermal radiation, peripheral distributed heating, and Y-shaped cooling channelsPhysics of Fluids · 2025
- Thermal Performance of Vented MHD Corrugated Enclosure: Effects of Cylinder Configuration for Nuclear and Electronics Cooling ApplicationsHeat Transfer · 2026
- Computational analysis of memory-dependent nonlocal response due to ramp-type heating under thermomass thermoelasticity theoryMathematics and Mechanics of Solids · 2025
- Effective Stress Analysis in a Magneto-Thermoelastic Medium Due to the Presence of Uniaxial Static StressesMathematics · 2026
- Numerical performance analysis of an active magnetic regenerator based on Fe doped La–A–Ca manganite oxides (A = Sr, Ba)Cryogenics · 2026