Strength of Wooden Truss Connections with Nail Plates Under Cyclic Humidity Changes.
Marek Wieruszewski, Adam Czerwiński, Agnieszka Katarzyna Wdowiak-Postulak, Maciej Jarzębski, Adrian Trociński
Department of Mechanical Wood Technology, Poznań University of Life Sciences, 60-637 Poznań, Poland. · Department of Materials Strength and Structural Diagnostics, Kielce University of Technology, 25-314 Kielce, Poland.
Key points
From the paper's conclusion- This study evaluated five continuous C24 Norway spruce reference specimens and fifteen specimens joined with GNA20-MIT nail plates using sequential four-point-bending stiffness measurements and wetting-drying conditioning.
Abstract
Metal-plate-connected (MPC) joints govern the stiffness and load-bearing performance of many prefabricated timber roof trusses, yet their response to repeated moisture changes remains critical for serviceability and durability. This study evaluated five continuous C24 Norway spruce reference specimens and fifteen specimens joined with GNA20-MIT nail plates using sequential four-point-bending stiffness measurements and wetting-drying conditioning. Test I was used as the initial stiffness stage, whereas Tests II and III followed successive 24 h water-immersion and 6-day natural-drying intervals; the specimens were subsequently tested to failure. The mean apparent modulus of elasticity of the MPC specimens decreased from 1.39 to 1.22 GPa (approximately 12%), but a Friedman repeated-measures test did not show a statistically significant stage effect (χ2(2) = 4.13, p = 0.127). Because the same specimens were repeatedly loaded, and no unexposed MPC control group was included, this change cannot be attributed exclusively to moisture cycling. In the primary analysis retaining all 15 MPC specimens, the mean apparent bending strength of the connected elements was 16.92 MPa, compared with 34.14 MPa for the structurally different continuous reference specimens; excluding M7 yielded 17.87 MPa only as a sensitivity analysis. Failure of the connected specimens was progressive and dominated by plate slip and partial spike withdrawal, whereas solid specimens failed more abruptly in bending. The results therefore support attention to connection flexibility and serviceability under variable environmental and loading histories, while further controlled testing is required to isolate the specific contribution of moisture cycling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Moisture Preparation and Bending Performance of Metal Plate Connected C24 Spruce Members in an Exploratory Comparison of Two Connector Systems.Polymers · 2026
- Quasi-Static Cyclic Response and Failure Modes of CNC-Machined Pinus radiata D. Don Plywood TIE Joints in the WikiHouse Skylark System: An Exploratory StudyForests · 2026
- Fatigue behavior of threaded rods bonded into glued-laminated timber for application in bridge constructionEuropean Journal of Wood and Wood Products · 2026
- Moment-resisting timber frames using mechanical fastener and adhesive connections: review and experimental testsCanadian Journal of Civil Engineering · 2026
- An experimental study on water migration near clay–caisson interface under long-term cyclic loadingMarine Georesources and Geotechnology · 2026
- Local contact behaviour of Norway spruce under compression parallel to fibresEuropean Journal of Wood and Wood Products · 2026