Materials (Basel, Switzerland)

Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models.

Berker Alpöz, Burçin Akan, Ender Akan

Department of Prosthodontics, Faculty of Dentistry, Izmir Katip Celebi University, 35620 Izmir, Türkiye. · Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, 35620 Izmir, Türkiye.

Key points

From the paper's conclusion
  • These findings indicate that support spacing is an important design parameter influencing the dimensional predictability of MSLA-printed dental models and highlight the value of region-specific accuracy assessment for optimizing support design in digital prosthodontic workflows.

Abstract

Additive manufacturing is increasingly integrated into digital prosthodontic workflows for the fabrication of dental models; however, printing-related parameters may influence the dimensional accuracy of clinically relevant regions. This in vitro study evaluated the effect of support spacing on the region-specific dimensional accuracy of masked stereolithography (MSLA)-printed dental models. A standardized typodont model representing a three-unit posterior fixed dental prosthesis preparation in the FDI 24-26 region was digitized to obtain a reference STL dataset. Three support spacing configurations were evaluated: 3 mm, 5 mm, and 7 mm (n = 8 per group). All specimens were fabricated using an MSLA printer and a photopolymer model resin at a layer thickness of 50 μm. After post-processing, the printed models were rescanned and compared with the reference dataset using three-dimensional deviation analysis. Root mean square (RMS) deviations were calculated for global, marginal, intaglio, and adjacent regions. Significant differences were observed in the global (p < 0.001), marginal (p = 0.001), and intaglio (p = 0.010) regions, whereas adjacent regions were not significantly affected (p = 0.070). Increasing support spacing was associated with greater dimensional deviations in the global and intaglio regions. Overall, the 3-mm support spacing demonstrated the most consistent dimensional performance across the evaluated regions. These findings indicate that support spacing is an important design parameter influencing the dimensional predictability of MSLA-printed dental models and highlight the value of region-specific accuracy assessment for optimizing support design in digital prosthodontic workflows.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models — Science Skim