Polyethylene Terephthalate Film-Based Sample Holder for Fixed-Target Serial Femtosecond Crystallography.
Jaehyun Park, Sehan Park, Ki Hyun Nam
Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 37673, Republic of Korea. · College of General Education, Kookmin University, Seoul 02707, Republic of Korea.
Key points
From the paper's conclusion- We introduce a polyethylene terephthalate (PET) film-based sample holder that can be applied to data collection for both small-molecule and macromolecule XFEL diffraction studies.
Abstract
Serial femtosecond crystallography (SFX) using X-ray free-electron lasers (XFELs) enables the determination of macromolecular and chemical structures along with minimizing radiation damage. Sample delivery using the fixed-target (FT) scanning method minimizes both sample consumption and physical damage during delivery. When XFELs penetrate the FT sample holder, background scattering generated from the holder material can interfere with data processing, which consequently indicates the importance of selecting an appropriate FT sample holder material according to specific experimental conditions. We introduce a polyethylene terephthalate (PET) film-based sample holder that can be applied to data collection for both small-molecule and macromolecule XFEL diffraction studies. Background scattering analysis revealed that the PET film-based sample holder produced relatively low X-ray scattering in the high-resolution range (<10 Å) compared with a nylon mesh-based sample holder composed of polyimide and nylon mesh. Conversely, background scattering generated from the PET film was relatively higher in the low-resolution range (>10 Å) than that with the polyimide film; however, this low-resolution background was negligible for data processing. Thin PET films were manually perforated to promote the deposition of microcrystals in random orientations. The crystal samples were then deposited onto the films and sealed with an additional PET film to prevent dehydration. Using the PET film-based sample holder, we successfully collected diffraction data from barium titanate without unwanted background scattering from the sample holder. Furthermore, the room-temperature structure of glucose isomerase was determined using the PET film-based sample holder. Therefore, PET film-based sample holders can be applied to both small-molecule and macromolecular SFX data collection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pattern orientation despite water-induced contrast reduction: a theoretical baseline for ultrafast single-particle X-ray imagingScientific Reports · 2026
- Shot-noise-limited X-ray powder diffraction from organic crystals with laser-driven femtosecond X-ray source.Journal of applied crystallography · 2026
- Ultrafast Liquid Jet X-ray Total ScatteringarXiv · 2026
- Spectrally resolved X-ray scattering.Faraday discussions · 2026
- Viscoelastic characterization of the lipid cubic phase provides insights into high-viscosity extrusion injection for XFEL experimentsScientific Reports · 2025
- High-background X-ray single particle imaging with 2D crystal holographic enhancement.Optics express · 2026