Technical Feasibility of Custom-Fabricated Auxetic Foam Insoles for Plantar Pressure Redistribution: An Exploratory Pilot and Bootstrap Resampling Investigation.
LaBreesha Batey, Enrique M Jackson, Changchun Zeng, Selvum Pillay
Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, 1075 13th St S, Birmingham, AL 35294, USA. · Material Science Branch, George C. Marshall Space Flight Center, National Aeronautics and Space Administration, 4631 Saturn RD, Huntsville, AL 35812, USA.
Key points
From the paper's conclusion- While initial cell-adaptation cycles were observed, custom insoles reduced PPP by up to 62.2% in systemic polyneuropathies, shifting signatures beneath the exploratory clinical safety target (<200 kPa) in 55% of simulated cases.
Abstract
Peripheral neuropathy degrades gait mechanics, elevating peak plantar pressures (PPP) and tissue ulceration risks. This exploratory pilot study evaluates custom orthotics using thermo-mechanically synthesized re-entrant auxetic foam insoles with targeted dome-shaped inserts. Bilateral dynamic gait analysis was conducted across a heterogeneous cohort (N = 9) utilizing a P-Walk 600 pressure plate and a MARVUE 2D motion capture system inside standardized footwear. To address small-sample limits, a non-parametric bootstrap resampling analysis (B = 1000) was executed. Native auxetic foam demonstrated high internal consistency ((σ*) = 12.063 kPa, Consistency Rank = 1), showing a strong numerical propensity to restrict load distribution variability compared to factory-installed over-the-counter (OTC) memory foam controls. While initial cell-adaptation cycles were observed, custom insoles reduced PPP by up to 62.2% in systemic polyneuropathies, shifting signatures beneath the exploratory clinical safety target (<200 kPa) in 55% of simulated cases. Conversely, customization triggered an adverse volumetric crowding effect in focal mononeuropathies, suggesting un-customized native auxetic foam as the preferred structural configuration for this specific cohort to avoid premature cell densification. Re-entrant cellular structures accommodate heterogeneous pathomechanics, offering an exploratory pathway for patient-specific orthotic optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and evaluation of a custom contoured pneumatic insole for active plantar pressure offloading.Journal of rehabilitation and assistive technologies engineering · 2026
- Bioinspired auxetic metamaterial liners and sockets for transtibial prostheses: Energy absorption and stress redistributionJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2025
- Finite Element-Based Biomechanical Evaluation of Patient-Specific Insoles for a Pediatric Patient with Hereditary Spastic Paraplegia Using the Taguchi MethodBioengineering · 2025
- Immediate effects of dynamic- and static-based custom insoles on structural alignment, pressure distribution and subjective comfort in paediatric flexible flatfoot.Frontiers in bioengineering and biotechnology · 2026
- From Mechanism to Manufacture: A Narrative Review of Insole Interventions Across Foot Deformity, Limb-Length Discrepancy, and Paediatric Orthopaedic Disease.Bioengineering (Basel, Switzerland) · 2026
- Improving offloading in diabetic feet: 3D-printed custom accommodative insoles outperform standard of care.PloS one · 2026