Life

PAR-SegNet: Feature-Level Pairwise Relation Modeling for Joint Fetal Head and Pubic Symphysis Segmentation in Intrapartum Ultrasound

Kaige Jiang, Li Zhang, Ming Jing, Cong Wang, Jingrun Zi

Computational

Key points

From the paper's conclusion
  • We evaluate the model using the 4000-image publicly released FH-PS-AOP Challenge training set for model development and the 1101-image non-overlapping subset of the PSFHS dataset for cross-dataset evaluation.

Abstract

Accurate segmentation of the pubic symphysis (PS) and fetal head (FH) is essential for Angle of Progression (AoP) estimation in intrapartum ultrasound (IUS). However, the specific construction of a shared pairwise relation from two independently parameterized projections of a common feature representation, followed by relation-guided asymmetric refinement, remains less explored in joint PS–FH segmentation. This study aimed to develop and evaluate PAR-SegNet for joint PS–FH segmentation in IUS. PARM constructs feature-level pairwise relations from discrepancies, interactions, and joint responses between two independently parameterized projections of the same bottleneck feature, and uses the learned relation to refine the two projection branches through separate paths. Enhanced Feature Recalibration (EFR) and Adaptive Multi-scale Context Aggregation (AMCA) are further incorporated to improve feature reliability under ultrasound interference and accommodate substantial target-scale differences, respectively. We evaluate the model using the 4000-image publicly released FH-PS-AOP Challenge training set for model development and the 1101-image non-overlapping subset of the PSFHS dataset for cross-dataset evaluation. On this evaluation set, PAR-SegNet achieves an overall DSC of 92.87%±0.17% and a mean absolute AoP estimation error of 8.02∘±0.21∘. In exploratory paired image-level comparisons with five high-performing methods, PAR-SegNet achieved significantly higher Overall DSC and PS DSC and a significantly lower mean absolute AoP estimation error than all five methods after Holm correction (padj<0.05). Its FH DSC was significantly higher than that of three methods but was not significantly different from nnU-Net v2 or VM-UNet.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

PAR-SegNet: Feature-Level Pairwise Relation Modeling for Joint Fetal Head and Pubic Symphysis Segmentation in Intrapartum Ultrasound — Science Skim