PAR-SegNet: Feature-Level Pairwise Relation Modeling for Joint Fetal Head and Pubic Symphysis Segmentation in Intrapartum Ultrasound
Kaige Jiang, Li Zhang, Ming Jing, Cong Wang, Jingrun Zi
Key points
From the paper's conclusion- We evaluate the model using the 4000-image publicly released FH-PS-AOP Challenge training set for model development and the 1101-image non-overlapping subset of the PSFHS dataset for cross-dataset evaluation.
Abstract
Accurate segmentation of the pubic symphysis (PS) and fetal head (FH) is essential for Angle of Progression (AoP) estimation in intrapartum ultrasound (IUS). However, the specific construction of a shared pairwise relation from two independently parameterized projections of a common feature representation, followed by relation-guided asymmetric refinement, remains less explored in joint PS–FH segmentation. This study aimed to develop and evaluate PAR-SegNet for joint PS–FH segmentation in IUS. PARM constructs feature-level pairwise relations from discrepancies, interactions, and joint responses between two independently parameterized projections of the same bottleneck feature, and uses the learned relation to refine the two projection branches through separate paths. Enhanced Feature Recalibration (EFR) and Adaptive Multi-scale Context Aggregation (AMCA) are further incorporated to improve feature reliability under ultrasound interference and accommodate substantial target-scale differences, respectively. We evaluate the model using the 4000-image publicly released FH-PS-AOP Challenge training set for model development and the 1101-image non-overlapping subset of the PSFHS dataset for cross-dataset evaluation. On this evaluation set, PAR-SegNet achieves an overall DSC of 92.87%±0.17% and a mean absolute AoP estimation error of 8.02∘±0.21∘. In exploratory paired image-level comparisons with five high-performing methods, PAR-SegNet achieved significantly higher Overall DSC and PS DSC and a significantly lower mean absolute AoP estimation error than all five methods after Holm correction (padj<0.05). Its FH DSC was significantly higher than that of three methods but was not significantly different from nnU-Net v2 or VM-UNet.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasoundFrontiers in Medicine · 2026
- Structure-Aware Perturbation Consistency Framework for Semi-Supervised Fetal Ultrasound Image Segmentation.IEEE journal of biomedical and health informatics · 2026
- Self-Perceived Boundary Refinement via Uncertainty for Efficient Intrapartum Ultrasound Image Segmentation.IEEE journal of biomedical and health informatics · 2026
- Cross-Sequence Robustness of Deep Learning for Placental MRI Segmentation: A Patient-Matched Study in Placenta Accreta Spectrum.Bioengineering (Basel, Switzerland) · 2026
- Semi-supervised Prostate Multi-Regional Semantic Segmentation with Patch-Based Plug-and-Play Correction Guidance.IEEE journal of biomedical and health informatics · 2026
- FUGC: Benchmarking Semi-Supervised Learning Methods for Cervical SegmentationIEEE Transactions on Medical Imaging · 2026