MET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing.
Jing-Hsuan Chen, Szu-Kai Fu, Jing-Jie Lin, Yuh-Chuan Shih, Chih-Yu Hsiao, Chia-Yu Tang, Yun-Chung Tseng, Fu-Shun Hsu
Graduate Institute of Sports Training, University of Taipei, Taipei 111036, Taiwan. · Department of Exercise and Health Sciences, University of Taipei, Taipei 111036, Taiwan.
Key points
From the paper's conclusion- This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing.
Abstract
Chemical protective clothing may increase metabolic demands during occupational tasks. This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing. Fifteen male participants completed 27 trials comprising three temperatures (15, 25, and 35 °C; 70% relative humidity) and nine workload conditions combining external loads (0, 10, and 20 kg) with locomotion speeds (4, 6, and 8 km/h). Metabolic responses during 15 min of treadmill locomotion were measured using a COSMED K5 portable metabolic system and analyzed using a two-way repeated-measures analysis of variance with pairwise comparisons. Intensity was classified based on group mean MET values. All conditions at 4 km/h were moderate intensity (3.8-5.3 METs), and all conditions at 8 km/h were vigorous intensity (9.0-12.8 METs). At 6 km/h, the no-load condition was moderate at 15 °C but vigorous at 25 °C and 35 °C, whereas both loaded conditions were vigorous at all temperatures. The repeated-measures ANOVA identified main effects of temperature and workload condition and a temperature-by-workload-condition interaction. After Bonferroni adjustment, MET values at 15 °C were lower than those at 35 °C in all nine workload conditions and lower than those at 25 °C in six conditions; 25 °C and 35 °C differed in one condition. These findings provide a practical reference for comparing the metabolic intensity of the tested workload conditions and may assist in planning training and occupational tasks performed in chemical protective clothing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Effect of Clothing on Thermal Stress of Workers in Confined SpacesJournal of Intelligent Decision Making and Information Science · 2026
- Meta-Analytic Study of Occupational Heat Stress in Healthcare Workers: Scientific Evidence to Guide the Design of Mitigation Strategies.Healthcare (Basel, Switzerland) · 2026
- Managing safety, functionality, and sustainability of fire-protective clothing: balancing burn prevention, physiological burden, and lifecycle safetyFrontiers in Public Health · 2026
- Comparison of Trajectory-Integrated, Stationary, and Wearable Methods for Estimating Thermal Exposure of Factory Workers: Associations Among Thermal Exposure, Fatigue, Thermal Sensation, and Workload.Sensors (Basel, Switzerland) · 2026
- Thermophysiological responses to occupational heat stress during simulated wildland firefighting in females and males: influence of fitness and body composition.Frontiers in physiology · 2026
- Developing a Personalized Occupational Heat Exposure Index.Environment & health (Washington, D.C.) · 2026