Impulse Oscillometry Findings in Children and Adolescents with Adrenal Insufficiency: An Exploratory Cross-Sectional Study.
Ercan Yılmaz, Erdem Topal, İsmail Dündar, Zeynep Yamancan Yılmaz, Nezihe Koker Ozer, Emine Çamtosun
Department of Pediatric Allergy and Immunology, Faculty of Medicine, Inonu University, 44280 Malatya, Turkey. · Department of Pediatric Endocrinology, Faculty of Medicine, Inonu University, 44280 Malatya, Turkey.
Key points
From the paper's conclusion- Because no healthy control group was included and the reference equations were derived from populations different from the study population, these findings should be interpreted as exploratory.
Abstract
BACKGROUND: Airway function in children with adrenal insufficiency (AI) has not been well characterized. We evaluated impulse oscillometry (IOS) findings in pediatric AI and compared patients with congenital adrenal hyperplasia (CAH) and AI due to causes other than CAH (non-CAH AI). METHODS: In this cross-sectional study, 52 children with AI underwent IOS. Oscillometric abnormalities were defined using z-score-based upper and lower limits of normal. IOS z-scores and clinical characteristics were compared between the CAH (n = 24) and non-CAH AI (n = 28) groups. RESULTS: The median age was 16 years (IQR, 6 years; min-max, 4-18 years), and 53.8% of participants were male. CAH was the most common etiology (46.1%). Median (IQR) IOS values were 0.49 (IQR, 0.32) kPa·L-1·s for R5, 0.29 (IQR, 0.13) kPa·L-1·s for R20, 0.20 (IQR, 0.16) kPa·L-1·s for R5-R20, -0.13 (IQR, 0.11) kPa·L-1·s for X5, -0.01 (IQR, 0.08) kPa·L-1·s for X20, 1.74 (IQR, 1.30) kPa·L-1 for AX, and 20.8 (IQR, 5.32) Hz for resonance frequency (Fres). The most frequent abnormality was reduced X5 (21.2%), followed by elevated R5 (19.2%), elevated R5-R20 (19.2%), reduced X20 (15.4%), elevated AX (15.4%), elevated R20 (13.5%), and elevated Fres (7.7%). No significant differences were observed between the CAH and non-CAH AI groups in demographic characteristics, atopic diseases, or any IOS parameter (all p > 0.05). CONCLUSIONS: A subset of children with AI had IOS measurements outside published parameter-specific reference limits. Among individual IOS parameters, measurements outside the applied reference limits were most frequently observed for X5, R5, and R5-R20. Because no healthy control group was included and the reference equations were derived from populations different from the study population, these findings should be interpreted as exploratory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Small Airway Dysfunction Assessed by Impulse Oscillometry in Children with Congenital Adrenal Hyperplasia: A Preliminary Case-Control Study.Journal of clinical medicine · 2026
- Impulse Oscillometry Detected Physiological Abnormalities More Frequently Than Spirometry in Children With Largely Preserved Lung Function.Acta paediatrica (Oslo, Norway : 1992) · 2026
- Allergic Rhinitis Duration and Small-Airway Dysfunction in Adolescents Without Asthma: A Cross-Sectional Impulse Oscillometry Study.The Journal of asthma : official journal of the Association for the Care of Asthma · 2026
- Impulse Oscillometry Reveals Altered Airway Mechanics in Children with Alternaria alternata Sensitization and Allergic Respiratory Disease.Journal of asthma and allergy · 2026
- Gastroesophageal Reflux Burden Before and After Exercise Challenge in Children with Poorly Controlled Asthma: A 48-Hour MII-pH Study.Advances in respiratory medicine · 2026
- Impulse oscillometry and traditional pulmonary function testing: correlation, advances and clinical implicationsBMJ Open Respiratory Research · 2026