Physiological Responses to a Sequential Higher-Frequency Low Tidal Volume Ventilation Protocol During Radiofrequency Atrial Fibrillation Ablation: A Single-Center Subgroup Proof-of-Concept Study.
Max Briefs, Maximilian A Jacobi, Astrid Bergmann, Marc P Woldt, Philipp Sommer, Vera von Dossow
Heart and Diabetes Center NRW, Institute of Anesthesiology and Pain Therapy, Ruhr University Bochum, 32545 Bad Oeynhausen, Germany. · Heart and Diabetes Center NRW, Department of Electrophysiology, Ruhr University Bochum, 32545 Bad Oeynhausen, Germany.
Key points
From the paper's conclusion- This post hoc single-center subgroup proof-of-concept study aimed to characterize physiological responses to HFLTV using left atrial pressure (LAP), gas exchange, and hemodynamic parameters during sequential, nonrandomized volume-controlled ventilation (VCV) and HFLTV.
Abstract
The physiological effects of mechanical ventilation are subject to ongoing research. Conventional ventilation may contribute to pulmonary volutrauma or barotrauma and influence cardiovascular physiology through changes in intrathoracic pressure. In the multicenter Ablate-by-LAWT study, patients undergoing atrial fibrillation ablation were ventilated using a higher-frequency, low tidal ventilation (HFLTV) protocol. This post hoc single-center subgroup proof-of-concept study aimed to characterize physiological responses to HFLTV using left atrial pressure (LAP), gas exchange, and hemodynamic parameters during sequential, nonrandomized volume-controlled ventilation (VCV) and HFLTV. The ventilation protocols differed in respiratory rate, tidal volume, PEEP, FiO2, and I:E ratio. Twelve patients were included, and differences between ventilation strategies were assessed using two-sided paired t-tests. Compared with VCV, HFLTV was associated with lower systolic LAP (Mean Difference (MD) -3.33 mmHg, 95% confidence interval (CI) [-5.61; -1.06], p = 0.008), whereas post hoc estimated mean LAP was similar between ventilation periods (MD -0.06 mmHg, 95% CI [-2.19; 2.08], p = 0.955). Heart rate (MD 8.1 bpm, 95% CI [3.8; 12.4], p = 0.002), mean arterial pressure (MD 11.5 mmHg, 95% CI [7.1; 15.9], p < 0.001), and cardiac index (MD 0.64 L/min/m2, 95% CI [0.29; 0.99], p = 0.002) were higher during HFLTV. The partial arterial pressure of oxygen (PaO2) was lower during HFLTV (MD -42.3 mmHg, 95% CI [-83.5; -1.1], p = 0.045, FDR-adjusted p = 0.072), and the partial arterial pressure of carbon dioxide (PaCO2) (MD -1.1 mmHg, 95% CI [-6.0; 3.7], p = 0.623) and the PaO2/FiO2 ratio (MD -49.3 mmHg, 95% CI [-105.2; 6.7], p = 0.079) did not differ significantly. Given the fixed-order design and simultaneous modification of multiple ventilatory parameters, these exploratory findings should be considered hypothesis-generating and cannot be attributed to individual components of the HFLTV protocol.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Frequency Low-Tidal Volume Ventilation and Procedural Efficiency in Atrial Fibrillation Catheter Ablation: A Single-Center Retrospective Study.Journal of cardiothoracic and vascular anesthesia · 2026
- High-frequency low-tidal-volume ventilation reduces loop catheter displacement during pulsed field ablation for pulmonary vein isolationJournal of Anesthesia · 2026
- Impact of Additional Left Atrial Posterior Wall Isolation During Pulsed-Field Ablation on Early Post-Ablation Autonomic Function in Persistent Atrial Fibrillation: A Heart-Rate-Variability-Based Cohort StudyJournal of Cardiovascular Development and Disease · 2026
- Hemodynamic characteristics in patients with permanent atrial fibrillation across different heart rate ranges and left ventricular ejection fraction levels using continuous non-invasive blood pressure monitoringJournal of Arrhythmology · 2026
- Hypertensive responses to exercise after 12-weeks of high-intensity interval training or moderate-to-vigorous intensity continuous training in patients with persistent and permanent atrial fibrillation: a non-prespecified post-hoc analysis of a randomized clinical trialJournal of science and medicine in sport · 2026
- The relationship between beat-to-beat variability in left ventricular inflow velocity and left ventricular filling pressure in patients with atrial fibrillationEuropean Heart Journal · 2026