Cerebral Perfusion and Oxygenation During Haemodialysis: A Systematic Review
Khaled Abdulwahab Amer, Faisal Saud Alhudaithi, Hassan Dhafer Alabisi, Yahia Mohammed Abumelha, Hasan Yahya Al Al Amer, Muath Majed AlQahtani, Ahmad Mohammed Alalmai, Nejad Mubasher Alnaem,
Key points
From the paper's conclusion- Methods: Six sources were searched up to 3 August 2026 for in vivo measurements of cerebral perfusion or oxygenation in adults on maintenance haemodialysis (protocol preregistered retrospectively).
Abstract
Background: Adults on maintenance haemodialysis carry a high burden of cognitive impairment, white-matter injury and stroke, part of which may be delivered by the treatment itself. We examined how cerebral perfusion and oxygenation change across a session, and whether the literature can support a summary. Methods: Six sources were searched up to 3 August 2026 for in vivo measurements of cerebral perfusion or oxygenation in adults on maintenance haemodialysis (protocol preregistered retrospectively). Risk of bias was rated across eight prespecified domains and certainty with GRADE. Pooling was admissible only within one technique family and across comparable measurement intervals; no analysis met that standard, so studies are synthesised narratively. Results: Of 1934 records screened, 126 reports of 116 studies were included; 77 reports from 76 cohorts yielded extractable data (32 oximetry, 27 transcranial Doppler, 20 perfusion imaging). Velocity fell in all five Doppler studies reporting paired within-session middle cerebral artery values, by 8.3% to 23.3% of the pre-dialysis value and by 16.0% to 23.3% in the three reporting a raw dispersion (49 participants). Perfusion imaging in two cohorts agreed in direction; certainty was very low. A randomised trial measuring grey-matter perfusion found no intradialytic change. Of 32 oximetry studies, 4 reported a within-session change with dispersion under 4 incompatible definitions. Only 3 of 77 measured both arterial pressure and carbon dioxide. Conclusions: Cerebral blood flow velocity falls during haemodialysis, but this should not be equated with a fall in tissue perfusion, and the oximetry literature cannot be synthesised as it stands. We propose a minimum reporting standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cerebral Blood Flow-Related Cognitive Impairment Is Mediated by Functional Connectivity in End-Stage Renal Disease Patients Undergoing Hemodialysis CBF-FC Mediation of Cognitive Impairment in Hemodialysis ESRD.Brain sciences · 2026
- Quantitative Electroencephalography in Hemodialysis: Scoping Review and Translational FrameworkJMIR Biomedical Engineering · 2026
- Altered microstructure in end-stage renal disease patients with maintenance hemodialysis: A diffusion kurtosis imaging analysis.Medicine · 2026
- Intradialytic Hemodynamic Instability and Delirium in Critically Ill Patients Receiving Renal Replacement Therapy: A Retrospective Cohort Study.Brain sciences · 2026
- Effectiveness of Nursing and Non-Pharmacological Interventions in Reducing Intradialytic Hypotension Among Haemodialysis Patients: A Systematic Review and Meta-Analysis.Nursing open · 2026
- Online hemodiafiltration for kidney failure: guidance and best clinical practice recommendations from the Italian Society of Nephrology.Journal of nephrology · 2026