Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report.
Dragan Klarić, Lea Katalinić, Marta Klarić
Department of Hemodialysis, General Hospital Zadar, 23000 Zadar, Croatia. · Department of Nephrology, University Hospital Centre Zagreb, 10000 Zagreb, Croatia.
Key points
From the paper's conclusion- This case demonstrates severe recurrent dialyzer-associated hypersensitivity with findings suggestive of complement involvement, complicated by cardiac arrest in a patient with markedly impaired cardiovascular reserve.
Abstract
Background: Dialyzer-associated hypersensitivity reactions are rare but potentially life-threatening complications of hemodialysis (HD). Their pathophysiology is heterogeneous. Methods: We report a 49-year-old patient with end-stage chronic kidney disease (CKD G5), severe secondary hyperparathyroidism, poorly controlled arterial hypertension, a long history of heavy smoking, severe coronary and valvular disease, reduced left ventricular ejection fraction, renal anemia, and chronic volume overload. Results: Shortly after initiation of HD with a polysulfone dialyzer (Diacap Pro), she repeatedly developed severe dyspnea, hypoxemia, and marked hypertensive responses. Similar reactions occurred after switching to a cellulose triacetate dialyzer (Sureflux), necessitating temporary conversion to peritoneal dialysis (PD). Progressive PD ultrafiltration failure and loss of residual kidney function eventually required a return to HD. Severe reactions recurred within 15-30 min of treatment despite premedication. During the most severe episode, the patient developed profound hypoxemia (SpO2 55%), severe hypertension (up to 240/130 mmHg), ventricular tachycardia, and cardiac arrest requiring successful cardiopulmonary resuscitation. Immunological evaluation demonstrated normal total IgE (17 U/mL), decreased C3 (0.76 g/L), markedly reduced total hemolytic complement activity (CH50, 18%), and elevated IL-6 (87.5 pg/mL). Chronic HD was successfully reinitiated using an FX CorAL dialyzer with a Helixone® hydro membrane. Since its introduction, no further hypersensitivity reactions have occurred, and corticosteroid, antihistamine, and bronchodilator premedication has been discontinued. This case demonstrates severe recurrent dialyzer-associated hypersensitivity with findings suggestive of complement involvement, complicated by cardiac arrest in a patient with markedly impaired cardiovascular reserve. Conclusions: Successful long-term treatment with a hydrophilic Helixone® dialyzer highlights the importance of individualized dialyzer selection in patients with severe hypersensitivity reactions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Systemic capillary leak syndrome during online hemodiafiltration leading to cardiac arrestRenal Replacement Therapy · 2026
- Blood Leak Alarms With Hydroxocobalamin Administration.American journal of kidney diseases : the official journal of the National Kidney Foundation · 2026
- Severe Diltiazem Poisoning Managed With CytoSorb Hemoadsorption and Supportive Therapies: A Case ReportCritical Care Explorations · 2026
- Intradialytic Hemodynamic Instability and Delirium in Critically Ill Patients Receiving Renal Replacement Therapy: A Retrospective Cohort Study.Brain sciences · 2026
- Treatment standards for hypotension on hemodialysis - physiology-based phenotyping of acute and chronic scenarios.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2026
- Association of Ultrafiltration Rate with Structural Remodeling of the Left Heart and Arrhythmias in Hemodialysis Patients: A Cross-Sectional Observational Study.Clinics and practice · 2026