Prediction of Three-Dimensional Soft Tissue Changes Following Mandibular PEEK Implantation (Proof of Concept).
Tom L Zwijnenberg, Rutger H Schepers, Johan Jansma, Haye H Glas
Clinic for Virtual Surgical Planning, 3D VSP B.V., Hoogwatum 2, 9906 TD Bierum, Groningen, The Netherlands. · Department of Oral and Maxillofacial Surgery, Expertcenter for Orthofacial Surgery, Martini Hospital Groningen, Van Swietenplein 1, 9728 NT Groningen, Groningen, The Netherlands.
Key points
From the paper's conclusion- Conclusions: These results demonstrate the potential of a computational approach for real-time prediction of facial soft tissue changes following PEEK implant placement, achieving clinically relevant accuracy at the cohort level, with a tendency towards under-prediction and one case exceeding the threshold.
Abstract
Background/Objectives: Polyetheretherketone (PEEK) implants are increasingly being used for mandibular reconstruction and augmentation, yet predicting the resulting facial soft tissue changes remains challenging. Accurate pre-operative prediction of soft tissue deformation is essential for surgical planning and patient counselling. To the best of our knowledge, this study presents the first application of a computational model for predicting three-dimensional facial soft tissue deformation induced by PEEK implants. Methods: Four patient cases with pre-operative and post-operative cone-beam computed tomography scans were analysed. A mass tensor model was employed to predict soft tissue changes based on the pre-operative soft tissue shape, mandibular anatomy, and the designed PEEK implant. Model accuracy was quantified by comparing predicted outcomes to post-operative scans using landmark-based analysis of chin and jaw positions, as well as surface distance mapping, with a mean error below 2 mm adopted as the criterion for clinically acceptable accuracy. Results: Landmark-based analysis revealed a mean absolute error of 0.9 ± 0.8 mm between the predicted and actual positions. The mean surface distances were 1.3 mm for the jaw-chin region and 1.0 mm for the entire facial region. Conclusions: These results demonstrate the potential of a computational approach for real-time prediction of facial soft tissue changes following PEEK implant placement, achieving clinically relevant accuracy at the cohort level, with a tendency towards under-prediction and one case exceeding the threshold.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes of patient-specific PEEK implants in craniomaxillofacial reconstruction: a systematic review and meta-analysis.International journal of oral and maxillofacial surgery · 2026
- Patient-specific implants in mandibular and temporomandibular surgery: a systematic review of current clinical evidence.Oral and maxillofacial surgery · 2026
- PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes.The British journal of oral & maxillofacial surgery · 2026
- Fused filament fabrication of radiopaque barium sulfate-reinforced polyetheretherketone composites for thin-walled patient-specific orbital reconstruction.Journal of materials science. Materials in medicine · 2026
- Towards minimally invasive prosthetic surgery of the temporomandibular joint: design and integrated CAD-FEM preclinical approach on the mini-pig.Computer methods in biomechanics and biomedical engineering · 2026
- The Pterygoid Anchorage Spatial Adequacy Concept: A CT-Based Morphometric Framework for Pterygoid Implant Planning.Journal of clinical medicine · 2026