Comparative Meta-Analysis: Salivary, Plasma, and Serum miRNA Profiles for Oral Squamous Cell Carcinoma Detection
Arbi Wijaya, Vera Julia, N Soedarsono, Turmidzi Fath, Bayu Brahma, Alif Rizqy Soeratman, Denni Joko Purwanto, Yutaro Higashi,
Tohoku University · University of Indonesia
Key points
From the paper's conclusion- Despite serum’s numerically superior performance, meta-regression revealed no significant matrix effect (Wald χ2 = 0.20, p = 0.903).
Abstract
Background: MiRNAs have emerged as minimally invasive biomarkers with considerable potential for the early detection of oral squamous cell carcinoma (OSCC). Although numerous studies have evaluated circulating miRNAs across different biofluids, the comparative diagnostic performance of saliva-, serum-, and plasma-derived miRNAs has not been systematically clarified. Methods: A meta-analysis was performed by screening PubMed, MEDLINE, Scopus, CINAHL, and related databases. Nineteen eligible studies evaluating miRNA-based assays in saliva, serum, or plasma were included. A random-effects bivariate model was used to calculate pooled sensitivity, specificity, and area under the HSROC curve. Meta-regression using log diagnostic odds ratio (lnDOR) examined whether biofluid type significantly influenced diagnostic performance. Results: Salivary miRNAs showed a pooled sensitivity of 0.76 (95% CI: 0.68–0.82; I2 = 84.69%), specificity of 0.79 (95% CI: 0.70–0.85; I2 = 70.41%), and an AUC of 0.84 (95% CI: 0.80–0.87). Plasma miRNAs produced comparable results with a pooled sensitivity of 0.77 (95% CI: 0.61–0.88; I2 = 90.45%), specificity of 0.79 (95% CI: 0.63–0.89; I2 = 80.20%), and an AUC of 0.85 (95% CI: 0.81–0.89). Serum-derived miRNAs demonstrated the highest accuracy with a pooled sensitivity of 0.82 (95% CI: 0.70–0.90; I2 = 76.92%), specificity of 0.88 (95% CI: 0.75–0.95; I2 = 74.87%), and an AUC of 0.91 (95% CI: 0.89–0.94). Despite serum’s numerically superior performance, meta-regression revealed no significant matrix effect (Wald χ2 = 0.20, p = 0.903). Conclusions: Although serum-derived miRNAs performed best overall, biofluid type was not a statistically significant determinant of diagnostic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Circulating microRNAs: a new era in early detection of oral squamous cell carcinoma (OSCC) - a systematic review and meta-analysis.Journal of the Egyptian National Cancer Institute · 2026
- Exploratory integrative machine learning analysis of miRNA datasets identifies a candidate miRNA signature for oral squamous cell carcinoma.Genomics & informatics · 2026
- Comparative Evaluation of Salivary Inflammatory Cytokines and microRNA Biomarkers Across the Spectrum of Oral Carcinogenesis.Cureus · 2026
- Diagnostic accuracy of salivary nucleic acid biomarkers in gastric cancer detection: a systematic review and meta-analysisCellular Oncology · 2026
- Multimodal Serum Profiling for Early Detection and Risk Assessment of Oral Potentially Malignant Disorders and Oral CancerAnalytical Chemistry · 2026
- Evaluation of salivary and serum Exosomal mRNAs as biomarkers for the diagnosis and prognosis of oral squamous cell carcinomaScientific Reports · 2025