Four-Dimensional Cine Cinematic Rendering of Structural Heart and Mechanical Circulatory Support Devices: An Illustrative Technical Experience.
Amy Avakian, Muhammad Umair
Southern Hills Hospital and Medical Center, Las Vegas, NV 89148, USA. · Department of Radiology, Columbia University Irving Medical Center, New York, NY 10032, USA.
Key points
From the paper's conclusion- We describe a demonstrative case series extending CR across the cardiac cycle-time-resolved "4D cine" CR-to depict dynamic device behavior and time-resolved multi-device interaction in a single volume; this is an illustrative technical experience rather than a systematic evaluation of diagnostic performance.
Abstract
Patients with implanted cardiac devices are a rapidly growing imaging population, and electrocardiogram-gated cardiac computed tomography (CT) is increasingly used to characterize device geometry, multi-device relationships, and dynamic behavior across the cardiac cycle. Cinematic rendering (CR) is a photorealistic three-dimensional (3D) visualization technique for cardiac CT whose established contribution in this population is communicative: it conveys 3D device geometry and material distinctions within a single rendered volume. We describe a demonstrative case series extending CR across the cardiac cycle-time-resolved "4D cine" CR-to depict dynamic device behavior and time-resolved multi-device interaction in a single volume; this is an illustrative technical experience rather than a systematic evaluation of diagnostic performance. Illustrative examples include an EVOQUE transcatheter tricuspid valve rendered together with concurrent surgical mitral and transcatheter aortic valves, a left atrial appendage occlusion device, a normally positioned Impella catheter, and a HeartMate 3 left ventricular assist device (LVAD). Across cases, 4D cine CR feasibility scaled inversely with metallic burden-the aggregate volume and radiodensity of metallic device components within the scan field-with renderings informative for low-metal nitinol and catheter devices but substantially degraded by streak artifact in high-metal LVAD housings. This relationship was observed qualitatively in a small selected series and is offered as an initial observation rather than an established characteristic of the technique. We discuss current limitations and emerging directions such as photon-counting detector CT, metal artifact reduction, and artificial-intelligence-assisted post-processing that may extend 4D cine CR in this population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cinematic rendering for characterization of anomalous coronary origins: visualization of interarterial courses and post-surgical assessment.Cardiology in the young · 2026
- Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs)medRxiv · 2026
- Black-Blood Cinematic Rendering of the Pulmonary Vasculature: A Negative-Contrast Intraluminal Preset.Tomography (Ann Arbor, Mich.) · 2026
- Real-time XR-based 6-DOF catheter tracking enhances cardiac intervention navigation efficiency and depth perception.npj biomedical innovations · 2026
- Cardiac Computed Tomography in Infective Endocarditis: A Radiological Perspective on Structural Complications and Emerging Diagnostic Technologies.Tomography (Ann Arbor, Mich.) · 2026
- Intraprocedural cardiac computed tomography-fluoroscopy image fusion guided structural heart intervention: a proof of concept experience during transcatheter aortic valve implantation.The international journal of cardiovascular imaging · 2026