Key points
From the paper's conclusion- This exploratory case report describes phase-related HRV variations obtained from a wearable device during a military CCR dive.
Abstract
Background: Heart rate variability (HRV) monitoring during real-world closed-circuit rebreather (CCR) diving remains methodologically challenging. This exploratory case report describes phase-related HRV variations obtained from a wearable device during a military CCR dive. Methods: A trained male military diver underwent continuous monitoring with a RootiRx® single-lead wearable device placed in a custom waterproof enclosure. Three consecutive 20 min segments were analyzed: pre-dive, CCR dive, and immediate post-dive. The post-dive segment was not acquired under standardized resting conditions, and the participant continued to wear the device throughout this period. RR interval data were analyzed using Kubios HRV Scientific 4.3.0 with medium-threshold artifact correction, smoothness-prior detrending (λ = 500), and 4 Hz interpolation. Time-domain, frequency-domain, and nonlinear HRV indices were evaluated descriptively. Results: Mean heart rate was 88.1 beats/min pre-dive, 102.8 beats/min during the dive, and 86.4 beats/min post-dive. SDNN values were 35.3, 29.9, and 49.2 ms, while RMSSD values were 29.7, 24.6, and 40.3 ms, respectively. The PNS index was -1.44, -2.08, and -1.10, and the SNS index was 1.66, 2.98, and 1.26 across the three phases. LF/HF values were 1.77, 1.46, and 3.92, respectively. Automatically corrected beats represented approximately 0.34%, 0.54%, and 0.46% of beats, with effective analyzable data proportions exceeding 99.7% in all three segments. Conclusions: An analyzable RR interval series was obtained across the three operational phases in this individual recording. However, the single-subject uncontrolled design, non-standardized recording conditions, multiple confounding factors, and absence of independent underwater validation prevent causal attribution of the observed differences to immersion, CCR exposure, or autonomic adaptation. Further controlled studies using validated underwater ECG systems are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-contact estimation of divers physiological indicators using iPPG and attention U-Net mechanism.Computers in biology and medicine · 2026
- Wearable Sensor System for Diver Vital Sign Monitoring.Military medicine · 2026
- Quantification of Heart Rate Variability as a Digital Biomarker for the Autonomic Control of Cardiac FunctionBiomolecules · 2026
- An observational study of the reliability and concurrent validity of heart rate variability devices in athletesFrontiers in Physiology · 2026
- Development of Physiological and Behavioral Indices for Assessing Diver Vulnerability in VR-Based Simulated DivingApplied Sciences · 2026
- Critical flicker fusion frequency assessment: robustness across photopic illumination in experienced divers.Frontiers in physiology · 2026