Journal of functional biomaterials

Biomechanical Effects of Pulpotomy Biomaterial Type and Thickness in Primary Molars: A Finite Element Analysis.

Yelda Polat Yavuz, Gizem Karagöz Doğan, İzzet Yavuz

Department of Pediatric Dentistry, Dicle University Faculty of Dentistry, 21280 Diyarbakır, Türkiye. · Department of Pediatric Dentistry, Iğdır University Faculty of Dentistry, 76000 Iğdır, Türkiye.

Key points

From the paper's conclusion
  • Background: This study aimed to evaluate the effects of three different biomaterials (MTA, Biodentine, BioAggregate) and two base thicknesses (2 mm, 3 mm) on stress distribution in a mandibular second primary molar model treated with pulpotomy using finite element analysis.

Abstract

Background: This study aimed to evaluate the effects of three different biomaterials (MTA, Biodentine, BioAggregate) and two base thicknesses (2 mm, 3 mm) on stress distribution in a mandibular second primary molar model treated with pulpotomy using finite element analysis. Methods: A sound mandibular second primary molar extracted for orthodontic reasons was scanned with micro-CT to create a detailed finite element model. Six models were prepared by combining three biomaterials (MTA, Biodentine, and BioAggregate) with two base thicknesses (2 mm and 3 mm). The models were evaluated under a 45° oblique occlusal loading condition, and von Mises stress distributions were analyzed in four anatomical regions: the cervical region of the mesial root, pulpal floor, furcation area, and cervical region of the distal root. Results: Compared with the 2-mm restorative configurations, the corresponding 3-mm configurations generally showed lower local stress values, particularly at the pulpal floor. However, the differences among the material and thickness combinations were relatively small. Conclusions: MTA, Biodentine, and BioAggregate exhibited similar biomechanical behavior in pulpotomized primary teeth. The 3-mm restorative configurations generally exhibited lower local stress levels than the corresponding 2-mm configurations. However, in clinical material selection, factors such as setting time, ease of application, and biocompatibility should also be taken into consideration alongside biomechanical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Biomechanical Effects of Pulpotomy Biomaterial Type and Thickness in Primary Molars: A Finite Element Analysis — Science Skim