Journal of functional biomaterials

Comparative Evaluation of Coronal Microleakage Associated with Different Intra-Orifice Barrier Protocols in Endodontically Treated Maxillary Anterior Teeth.

Ceren Turan Gökduman, Esra Arılı Öztürk, Mediha Büyükgöze-Dindar

Private Clinic, 39000 Kırklareli, Türkiye. · Private Clinic, 59000 Tekirdağ, Türkiye.

Randomised · n=10

Key points

From the paper's conclusion
  • Under the experimental conditions of this ex vivo study, the protocols involving the EQ and both bulk-fill resin composites (FR, EF) resulted in significantly lower coronal dye penetration than the protocols involving the TNF, IS and the no-IOB control.

Abstract

Preventing coronal microleakage is crucial for long-term endodontic success; this ex vivo study compared the sealing performance of five intra-orifice barrier (IOB) material application protocols with that of a no-IOB control. Sixty maxillary anterior teeth were randomly assigned to six groups (n = 10): control, flowable composite, universal composite, resin-modified glass ionomer cement (RMGIC), high-viscosity bulk-fill composite, and flowable bulk-fill composite. Following endodontic treatment, 2 mm-thick barriers were placed in five groups. All specimens underwent 1000 thermocycles and 24 h immersion in 2% methylene blue. Linear dye penetration was measured at ×50 using stereomicroscopy and ImageJ. Data were analyzed using one-way ANOVA with Tukey's HSD test (α = 0.05). Microleakage differed significantly among groups (F (5, 54) = 12.473; p < 0.001). The lowest mean microleakage was observed with the Estelite Sigma Quick (EQ) (1.85 ± 0.59 mm), followed by the Estelite Bulk Fill Flow (EF) (2.28 ± 0.91 mm) and Filtek One Bulk Fill Restorative (FR) (2.48 ± 1.18 mm). No statistically significant differences were detected among these materials; however, each demonstrated significantly less microleakage than the Tetric N-Flow (TNF), Ionoseal (IS), and no-IOB control (p < 0.05), among which no differences were detected (p > 0.05). Under the experimental conditions of this ex vivo study, the protocols involving the EQ and both bulk-fill resin composites (FR, EF) resulted in significantly lower coronal dye penetration than the protocols involving the TNF, IS and the no-IOB control.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparative Evaluation of Coronal Microleakage Associated with Different Intra-Orifice Barrier Protocols in Endodontically Treated Maxillary Anterior Teeth — Science Skim