Comparative Analysis of the Fibroblastic Response and Collagen and Elastic Fiber Formation After Implantation of Polypropylene Versus an Electrospun Biodegradable Polymer for Reinforcement of the Musculo-Fascial Wall.
Igor A Eisenach, Elena L Lushnikova, Galina A Lapii, Alexey V Kuznetsov, Larisa Y Kostina
Institute of Molecular Pathology and Pathomorphology, Federal Research Center for Fundamental and Translational Medicine, 2 Timakova St., Novosibirsk 630117, Russia. · Federal State Budgetary Educational Institution of Higher Education, Novosibirsk State Medical University, Ministry of Health of Russia, 52 Krasniy Prospekt, Novosibirsk 630091, Russia.
Key points
From the paper's conclusion- These findings are consistent with the good extensibility and low tear resistance of newly formed connective tissue.
Abstract
The replacement of polypropylene with biodegradable polymers for surgical reinforcement of musculo-fascial structures is of considerable clinical interest. A study in 98 laboratory rats with implanted polypropylene or biodegradable biopolymer demonstrated the formation of dense irregular connective tissue at the surgical site instead of biopolymer and dense regular connective tissue around the polypropylene. The fibroblastic response to the biopolymer lagged behind that to polypropylene by approximately nine months, reflecting gradual polymer degradation, but did not differ between groups at 12 months, when the biopolymer had completely biotransformed. In both groups, newly formed connective tissue contained numerous elastic fibers and relatively fewer type I (COLI) and type III (COLIII) collagen fibers compared with intact preoperative tissue. In peri-implant tissue from both groups, COLIII fibers significantly predominated over COLI, with a higher volume fraction of COLIII around the polypropylene than around the biopolymer, whereas COLI was significantly more abundant in intact tissues. These findings are consistent with the good extensibility and low tear resistance of newly formed connective tissue. In the polypropylene group, polymer filaments reinforced this tissue mechanically. Further analysis of explanted tissues is required to determine the functional properties of connective tissue remodeled at the site of a degraded biopolymer implant.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research Progress on Preparation and Biocompatibility of Degradable Polymeric Materials for Soft Tissue Repair2026
- Early-stage stability and degradation of patient-specific biodegradable 3D-printed implants for critical mandibular reconstructionDental Materials · 2026
- Polycaprolactone Scaffolds for BONE Regeneration in Animal Models of Cranial Defects: A Systematic Review and Meta-Analysis.Journal of functional biomaterials · 2026
- Macroscopic, radiologic, and microscopic analysis of explanted abdominal wall prosthesis.Hernia : the journal of hernias and abdominal wall surgery · 2026
- Biodegradable Vascular Patches for Arterial Reconstruction: In Vitro Study and Long-Term Implantation in a Sheep Model.Biomedicines · 2026
- 3D-printed scaffold-based strategies for enthesis regeneration: a systematic review of the literature.Frontiers in bioengineering and biotechnology · 2026