Journal of Composites Science

Calibration of Numerical Structural Model of UAV Composite Wing with Experimental Static Bending Test

Vítor M. T. Silva, André C. Marta

Key points

From the paper's conclusion
  • Based on the structural response of a 12 m span unmanned aerial vehicle (UAV) composite wing that is subject to a static bending test at limit load, the comparison of the vertical displacement and torsional rotation between the experiment and the FEM exhibited significant discrepancies of up to −154.1%.

Abstract

With the increasing use of finite element method (FEM) analyses not only to design but also to ensure the structural safety of complex aerospace composite structures, it is paramount to have calibration practices to validate the computational models. A large portion of the work in the literature focuses on complex calibration that depends on ground vibration testing to calibrate modal responses. Therefore, it is valuable to provide a workflow to calibrate structural models that are based on sparse static displacements, which are much easier to obtain. This work addresses this gap. Based on the structural response of a 12 m span unmanned aerial vehicle (UAV) composite wing that is subject to a static bending test at limit load, the comparison of the vertical displacement and torsional rotation between the experiment and the FEM exhibited significant discrepancies of up to −154.1%. A sensitivity analysis showed that the Young’s modulus and ply thicknesses governed the bending response, while the wingbox position and fiber orientations mostly impacted torsion. A four-phase calibration process that is based on first-order derivatives of the wing tip displacement and rotation with respect to the identified mechanical and geometric parameters determined the required change for each parameter to eliminate the numerical discrepancies. Applying the estimated parameter value changes by linear extrapolation resulted in an over-corrected model response, but tuning the changes proved to be sufficient to improve the model satisfactorily. The final calibrated model reduced the displacement prediction error from −43% to −22% and the tip rotation error from −154% to +15.9%, putting it within the experimental uncertainty. The proposed calibration process, while practical and simple, has been shown to be capable of significantly improving the accuracy of FEM analyses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers