Impact of Pelvic Bone Marrow Dosimetry on Acute Hematologic Toxicity in Cervical Cancer During Pelvic Intensity-Modulated Radiation Therapy
Yuanjing Wang, Siqi Guan, Ming Wang, Yin Lv
Key points
From the paper's conclusion- Conclusions: In this exploratory cohort, pelvic bone marrow V25 > 61.146% and V35 > 37.173% were associated with grade III–IV acute hematologic toxicity in cervical cancer patients receiving concurrent chemoradiation with prophylactic extended-field radiation therapy.
Abstract
Purpose: In advanced cervical cancer, external beam radiotherapy (EBRT) is recommended to be delivered using intensity-modulated radiation therapy (IMRT)/volumetric modulated arc therapy (VMAT). The incidence of acute hematologic toxicity (HT) may increase due to the pelvic bone marrow exposure to the low-dose–volume. This study aimed to investigate factors impacting the incidence of acute HT in this population. Methods: A cohort of 80 cervical cancer patients treated with concurrent chemoradiation and prophylactic extended-field radiation therapy from January 2020 to January 2024 was analyzed. All patients received VMAT. Firth penalized logistic regression was used to identify clinical and dosimetric factors associated with acute HT. Clinical factors included age, cancer stage, pathological type, primary tumor size, number of lymph node metastases, and albumin levels. Pelvic dosimetric parameters included V5, V10, V15, V20, V25, V30, V35, V40, V45, V50, Dmin, Dmax, and Dmean. Acute HT severity was graded using the Radiation Therapy Oncology Group (RTOG) acute radiation morbidity criteria. Results: Lower pre-radiotherapy serum albumin levels and higher pelvic bone marrow V20, V25, V30, and V35 values were associated with the incidence of grade III–IV acute hematologic toxicity (all p < 0.05). The dose–volume parameters showed acceptable predictive value (areas under the ROC curve: V20 0.787, V25 0.771, V30 0.762, and V35 0.781), and exceeding the ROC-derived cutoff thresholds for V20, V25, V30, and V35 was associated with a significantly higher incidence of grade III–IV acute HT (all p < 0.01). In multivariable Firth penalized logistic regression, V25 > 61.146% (OR = 4.173, 95% CI: 0.626–27.828) and V35 > 37.173% (OR = 3.230, 95% CI: 0.571–18.282) were associated with increased odds of grade III–IV acute HT, although without statistical significance in multivariable analysis (p = 0.140 and p = 0.185, respectively). Conclusions: In this exploratory cohort, pelvic bone marrow V25 > 61.146% and V35 > 37.173% were associated with grade III–IV acute hematologic toxicity in cervical cancer patients receiving concurrent chemoradiation with prophylactic extended-field radiation therapy. Since this is an exploratory study, further independent cohorts are needed to further validate the dose–volume thresholds constructed in this study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Acute Hematological Toxicities Between Three-Dimensional Conformal Radiotherapy (3DCRT) and Intensity-Modulated Radiotherapy (IMRT) in Locally Advanced Cervical Cancer.Cureus · 2026
- Pelvic bone marrow dosimetry predicts grade ≥ 2 hematologic adverse events in locally advanced rectal cancer.Radiation oncology (London, England) · 2026
- Incidence, characteristics, and exploratory analysis of factors associated with pelvic osteitis/osteoradionecrosis after radiotherapy for cervical cancer: a single-center retrospective cohort study with an unmatched case-control analysis.Translational cancer research · 2026
- Dosimetric Comparison of One-, Two-, Three-, and Four-Arc Volumetric Modulated Arc Therapy Plans in Cervical Carcinoma: Evaluation of Plan Quality, Organ-at-Risk Sparing, and Treatment Efficiency.Cureus · 2026
- Development and internal validation of a predictive model for thrombocytopenia in cervical cancer patients undergoing concurrent chemoradiotherapy.BMC cancer · 2026
- Blood dosimetry during volumetric modulated arc therapy for non-small cell lung cancer: A time-resolved model of circulating particles.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026