Sustaining High-Dose Hemodiafiltration in Routine Clinical Practice: A Retrospective Evaluation of a Quality Improvement Intervention
Younes Bathish, Louisa Rostom, Elite Elkobi, Alaa Safia
Key points
From the paper's conclusion- These findings support a standardized, multistep intervention for sustaining high-volume HDF in a real-world environment without increasing the time burden of treatments.
Abstract
Background: High-volume post-dilution online hemodiafiltration (HDF) may improve clinical outcomes, but consistent delivery of the required convective dose remains difficult in routine practice. We evaluated whether a structured, multistep quality improvement intervention could increase and sustain the proportion of treatments achieving a convection volume of at least 23 L per session. Methods: This single-center retrospective study included 54 adults receiving maintenance post-dilution online HDF between January 2021 and December 2024. Three periods were examined: pre-intervention (T0; January 2021–June 2023), implementation (T1; July–December 2023), and maintenance (T2; January–December 2024). The intervention addressed blood flow, vascular access practices, access recirculation, anticoagulation, access dysfunction, and staff education. Repeated measures were compared using the Friedman test. Multivariable linear regression and linear mixed-effects models assessed factors associated with target achievement. Results: Median target achievement of high-volume HDF was 39.7% (17.9–66.2) during the pre-intervention period (T0), 41.4% (16.1–72.2) during implementation (T1), and 81.9% (70.4–95.0) during maintenance (T2) (p < 0.001). Prescribed blood flow increased from 291 mL/min at T0 to 307 mL/min at T1 and 373 mL/min at T2 (p < 0.001), while effective Kt/V increased from 1.2 at T0 and T1 to 1.4 at T2 (p < 0.001). Median interdialytic weight gain remained stable. At the treatment-session level, target achievement among AVF/AVG sessions was 44.6% at T0, 44.8% at T1, and 82.5% at T2; corresponding values among tunneled-catheter sessions were 38.2%, 45.2%, and 75.5%, respectively. Treatment duration showed a statistically significant but clinically small difference across periods, without sustained prolongation. In the mixed-effects models, higher blood flow was independently associated with target achievement (B = 0.342 per mL/min; 95% CI 0.268–0.415; p < 0.001). Conclusions: A structured quality improvement program was associated with a large and sustained increase in high-volume HDF delivery. The improvement coincided principally with higher blood flow and better dialysis adequacy rather than longer treatment time. These findings support a standardized, multistep intervention for sustaining high-volume HDF in a real-world environment without increasing the time burden of treatments. Controlled multicenter studies are needed to confirm generalizability, safety, and sustainability over time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hemodiafiltration: Clinical Practice of Today and a Look into the Future.Journal of the American Society of Nephrology : JASN · 2026
- On-Line High-Volume Hemodiafiltration: Current Evidence and Clinical Outcomes.Contributions to nephrology · 2026
- Online hemodiafiltration for kidney failure: guidance and best clinical practice recommendations from the Italian Society of Nephrology.Journal of nephrology · 2026
- Advancing Water and Dialysate Standards for High-Volume Hemodiafiltration in the United States: From Scientific Rationale to Clinical Implementation.Kidney360 · 2026
- The Role of Online Hemodiafiltration in Contemporary Kidney CareClinical Journal of the American Society of Nephrology · 2025
- On-Line High-Volume Hemodiafiltration: Mechanisms and Equipment.Contributions to nephrology · 2026