Journal of clinical medicine

Pulmonary Vessel Control During Minimally Invasive Anatomical Lung Resection: A Retrospective Intercentre Comparison of Selective Polymer Clip Use and Stapler-Only Cohorts.

Krzysztof Walczak, Maciej Dancewicz, Roman Lewandowski, Aleksandra Szlachcińska

Department of Thoracic Surgery, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, ul. 3-go Maja 13, 41-800 Zabrze, Poland. · Clinical Department of Thoracic Surgery and Tumors, Oncology Centre, ul. Dr I. Romanowskiej 2, 85-796 Bydgoszcz, Poland.

Observational · n=202

Key points

From the paper's conclusion
  • We compared selective Click’aV/Click’aV Plus clip use, often combined with vascular stapling, with stapler-only vessel control.

Abstract

Background/Objectives: Comparative evidence for pulmonary vessel control with polymer clips and staplers is limited. We compared selective Click'aV/Click'aV Plus clip use, often combined with vascular stapling, with stapler-only vessel control. Methods: This retrospective intercentre study included adults undergoing minimally invasive lobectomy or segmentectomy at four Polish centres. Two centres contributed each cohort, with no within-centre comparison in the analysed dataset. The prespecified non-inferiority margins were 100 mL for recorded blood loss and 30 min for operative time, tested hierarchically. Qualitative blood-loss records were recoded to their upper thresholds. Results: The analysis included 202 patients: 99 with selective clip use (CLIC) and 103 with stapler-only control (COMP). Threshold entries comprised 64.5% of available CLIC and 51.5% of COMP blood-loss records. The blood-loss criterion was met under upper-threshold recoding (permutation estimate, 36.8 mL; nominal one-sided 95% upper confidence bound, 72.1 mL; p = 0.0016). Operative-time non-inferiority was not demonstrated (difference, 19.3 min; upper bound, 33.9 min; p = 0.1101). Post hoc propensity-score matching yielded 79 pairs and consistent non-inferiority decisions. Conclusions: The prespecified blood-loss success criterion was met, whereas operative-time non-inferiority was not demonstrated. Centre confounding, unmodelled within-centre correlation and threshold-based blood-loss recording preclude attribution to the devices alone; the findings contribute hypothesis-generating post-market clinical follow-up evidence.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers