Journal of clinical medicine

Deep Learning Reconstruction for High-b-Value FOCUS DWI in Pancreatic Cancer: Image Quality Improvement and Effects on ADC Measurements.

Chengxin Wan, Yuwei Wang, Lanling Zhang, Ruinan He, Yong Chen, Bin Yu, Bin Lu, Li Tao,

Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China. · Department of Hepatobiliary Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.

Computational · n=68

Key points

From the paper's conclusion
  • Objectives: To evaluate whether deep learning reconstruction (DLR) improves pancreas-referenced image quality in high-b-value field-of-view optimized and constrained undistorted single-shot diffusion-weighted imaging (FOCUS DWI) for pancreatic cancer, and to assess reconstruction-related changes in apparent diffusion coefficient (ADC) measurements in tumor and non-tumorous pancreatic regions.

Abstract

Objectives: To evaluate whether deep learning reconstruction (DLR) improves pancreas-referenced image quality in high-b-value field-of-view optimized and constrained undistorted single-shot diffusion-weighted imaging (FOCUS DWI) for pancreatic cancer, and to assess reconstruction-related changes in apparent diffusion coefficient (ADC) measurements in tumor and non-tumorous pancreatic regions. Methods: This prospective single-center study included 68 patients with pathologically confirmed pancreatic cancer who underwent 3.0-T pancreatic MRI. FOCUS DWI was acquired with b values of 0, 1000, 1500, and 2000 s/mm2 and reconstructed with and without DLR. Quantitative metrics included lesion signal-to-noise ratio (SNR), lesion-to-pancreas contrast-to-noise ratio (CNR), lesion-to-pancreas signal intensity ratio (LP-SIR), and ADC values in tumor regions and non-tumorous pancreatic parenchyma. Two abdominal radiologists independently assessed composite image quality and lesion conspicuity using a 5-point ordinal scale. Paired comparisons were performed with Holm correction across b values. Results: DLR significantly increased lesion SNR and lesion-to-pancreas CNR at b = 1000, 1500, and 2000 s/mm2 (all Holm-adjusted p < 0.001). Absolute image quality was highest at b = 1000 s/mm2, whereas the greatest DLR-related lesion SNR gain occurred at b = 1500 s/mm2. LP-SIR remained broadly stable after DLR (Holm-adjusted p = 0.767, 1.000, and 1.000). Tumor regions showed lower ADC values than non-tumorous pancreatic parenchyma across all b values and reconstruction conditions (all p < 0.001), while ADC values did not differ significantly between DLR and non-DLR reconstructions within either region (p = 0.414-0.794). Qualitative scores improved after DLR for both readers at all b values (all Holm-adjusted p < 0.001), with weighted κ ranging from 0.717 to 0.896. Conclusions: DLR improved ROI-based quantitative image-quality metrics and qualitative image assessment in high-b-value pancreatic FOCUS DWI, with the greatest lesion SNR gain at b = 1500 s/mm2. No statistically significant reconstruction-related differences in ADC measurements were observed within tumor or non-tumorous pancreatic regions.

Read the paper