Journal of clinical medicine

Femorally Inserted Central Catheter Ports with a Suprainguinal Reservoir: A Preliminary Single-Center Experience.

Hyuckjin Kwon, Lyo Min Kwon, Jung Ho Park, Bum Jun Kim, Ho Young Kim

Division of Pediatric Cardiology, Department of Pediatrics, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea. · Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si 14068, Republic of Korea.

Observational · n=19

Key points

From the paper's conclusion
  • Conclusions: This preliminary single-center experience supports the technical feasibility of femoral port implantation with a suprainguinal reservoir in carefully selected patients for whom upper-body venous access is unsuitable.

Abstract

Background/Objectives: Totally implantable venous access devices (TIVADs) provide long-term venous access for chemotherapy and supportive care. When conventional upper-body venous access is unsuitable, a femorally inserted central catheter port (FICC-port) may be considered. This study describes a suprainguinal reservoir configuration and reports preliminary technical and clinical outcomes. Methods: In this retrospective single-center study, 20 femoral port procedures were performed in 19 patients between February 2023 and April 2026. All procedures used ultrasound-guided right common femoral venous access, with a suprainguinal reservoir on the lateral lower abdominal wall. Outcomes included technical success, procedure time, complications, device status at the end of follow-up, and the cumulative incidence of complication-related port removal in an exploratory competing-risk analysis. Results: All 20 procedures were technically successful (100%; exact 95% confidence interval [CI], 83.2-100%), with a mean procedure time of 17.2 ± 10.2 min. One late infection required port removal (1/20, 5.0%; exact 95% CI, 0.1-24.9%; 0.37 per 1000 catheter-days). No clinically detected catheter-related thrombosis or mechanical complication was recorded (0/20 for each; exact 95% CI, 0-16.8%). With death and elective removal treated as competing events, the cumulative incidence of complication-related removal was 6.4% at 90 days. The median observed indwelling duration was 149.5 days (range, 3-458 days). Conclusions: This preliminary single-center experience supports the technical feasibility of femoral port implantation with a suprainguinal reservoir in carefully selected patients for whom upper-body venous access is unsuitable. The small cohort and limited follow-up do not establish comparative or long-term safety.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers