Journal of clinical medicine

Inspiratory Versus Paired Expiratory CT in Established Bronchiolitis Obliterans Syndrome After Allogeneic Hematopoietic Stem-Cell Transplantation: A Multi-Reader Agreement Study.

Julien G Cohen, Louise Bondeelle, David Leite-Arada, Julia Langhart, Federica Giannotti, Sarah Morin, Pierre-Alexandre Poletti, Anne Bergeron

Division of Radiology, Diagnostic Department, Geneva University Hospitals (HUG), Rue Gabrielle-Perret-Gentil 4, 1205 Geneva, Switzerland. · Division of Pulmonology, Geneva University Hospitals (HUG), 1205 Geneva, Switzerland.

Observational · n=14

Key points

From the paper's conclusion
  • We compared inspiratory with expiratory CT, with and without minimum-intensity projection (MinIP), for assessing small-airway involvement.

Abstract

Background/Objectives: Bronchiolitis obliterans syndrome (BOS) is the only pulmonary manifestation of graft-versus-host disease recognized after allogeneic hematopoietic stem-cell transplantation (HSCT). Air trapping, a supporting diagnostic feature, requires paired inspiratory and expiratory CT, increasing radiation exposure. We compared inspiratory with expiratory CT, with and without minimum-intensity projection (MinIP), for assessing small-airway involvement. Methods: In this retrospective exploratory study, 14 patients with post-HSCT BOS underwent inspiratory and expiratory volumetric CT. Five blinded readers scored lobular hypoattenuation (inspiratory mosaic attenuation; expiratory air trapping) in six lung zones on native and MinIP reconstructions. Agreement, reproducibility and functional correlation were analyzed. Results: Native inspiratory and expiratory scores showed no systematic difference (mean difference -0.21; 95% CI, -0.96 to 0.54; within a ±2-point exploratory equivalence margin, p < 0.001) and substantial agreement (weighted κ = 0.80). Inter-reader reproducibility was moderate, highest for native inspiration (intraclass correlation coefficient, 0.57), which correlated most strongly with the forced expiratory flow at 25-75% z-score (ρ = -0.75); differences between native phases were not significant. MinIP increased scores but reduced reproducibility and functional correlation. Conclusions: In established BOS, native inspiratory CT agreed substantially with expiratory CT without systematic difference, but individual differences preclude conclusions on diagnostic interchangeability. Prospective studies including early disease are needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers