Distinguishing Post-LASIK Ablation Patterns on Corneal Tomography: Comparing Clinician Versus Large Language Model.
Andrea C Vazquez-Loreto, Sanjana Molleti, Hanna Pawlowski, Calisa G Lee-Choi, Cole S Elsner, Mina M Sitto, Gabriel N Medina, Niki C Feiz,
College of Medicine, University of Arizona-Phoenix, Phoenix, AZ 85004, USA. · Hoopes Vision, Hoopes Moshirfar Research Center, Draper, UT 84020, USA.
Key points
From the paper's conclusion- Conclusions: The overall accuracy of ChatGPT-5.5 did not meet that of the clinician while ability to identify myopic and hyperopic ablation patterns was comparable.
Abstract
Background: The purpose of this study is to assess the ability of generative AI and a refractive surgeon to distinguish post-LASIK Scheimpflug tomography images based on original excimer laser ablation and to recognize untreated corneas. Methods: Corneal tomography Pentacam images from 204 eyes, which included hyperopic ablations, myopic ablations, myopic astigmatic ablations, mixed astigmatic ablations, or untreated eyes, were compiled. These were individually queried in ChatGPT-5.5 using a multiple-choice prompt to obtain a response. A refractive surgeon was also tested on the same 204 corneas. Results: The clinician obtained higher overall accuracy (85.8% [95% CI 80.2-90.3]) compared to ChatGPT, (60.3% [95% CI 53.2-67.1], p < 0.001) and was significantly more likely to answer correctly overall based on McNemar's test. Additionally, ChatGPT underperformed in the myopia with astigmatism, mixed astigmatism, and untreated categories, with sensitivities of 38%, 6.3%, and 76%, respectively. Conclusions: The overall accuracy of ChatGPT-5.5 did not meet that of the clinician while ability to identify myopic and hyperopic ablation patterns was comparable. Both the AI model and the clinician had decreased accuracy in myopic astigmatism and mixed astigmatism ablation patterns, though the clinician still performed significantly better. Further studies involving alternative AI models, multicenter data, and standardized evaluation protocols are warranted to establish the clinical applicability of these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence Applications in Laser-Assisted Refractive Surgery-A Comprehensive Review.Diagnostics (Basel, Switzerland) · 2026
- Can artificial intelligence match refractive surgeons?: A comparative analysis of refractive surgery candidate selection.Medicine · 2026
- An Explainable AI Framework for Corneal Imaging Interpretation and Refractive Surgery Decision SupportBioengineering · 2025
- Artificial Intelligence–Derived Biomechanical Index for Early Corneal Ectasia Detection: Advancing Beyond TomographyOphthalmology Science · 2025
- Machine learning quantitative OCT derived fibrosis indicators for corneal haze evaluation.PloS one · 2026
- Assessing the quality and educational applicability of AI-generated anterior segment images in ophthalmologyScientific Reports · 2025