Impact of a Reminder App on Bladder Filling During Moderately Hypo-Fractionated Radiotherapy for Prostate Cancer: Results of the REFILL-PAC-HYPO Trial.
Dirk Rades, Stefan Janssen, Laura Doehring, Jan-Dirk Küter, Michael von Staden, Ahmed Al-Salool, Julia Koeck, Justus Domschikowski,
Department of Radiation Oncology, University of Luebeck, 23562 Luebeck, Germany. · Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Luebeck Campus, 23538 Luebeck, Germany.
Key points
From the paper's conclusion- This non-randomized multicenter REFILL-PAC-HYPO trial with external control evaluated the association between use of the reminder app and bladder filling during a radiotherapy course.
Abstract
Background/Objectives: Moderate hypo-fractionation is frequently used for irradiation of prostate cancer. Irrespective of dose fractionation, radiotherapy can lead to radiation cystitis. To reduce urinary toxicity, it is important to avoid bladder volumes < 200 mL. This may be facilitated with an app reminding patients to drink water prior to irradiation. This non-randomized multicenter REFILL-PAC-HYPO trial with external control evaluated the association between use of the reminder app and bladder filling during a radiotherapy course. Methods: Twenty-two patients receiving hypo-fractionated irradiation (20 × 3.0 Gy) were planned to be supported by the app (the prospective experimental group) and compared to 95 patients who were not supported by the app (the historical control group). The primary endpoint was the number of fractions with a bladder volume < 200 mL. Secondary objectives included satisfaction with the app and its impact on using health technology. Results: The median number of fractions with a bladder volume < 200 mL was lower in the app-supported experimental group (13; interquartile range: 6, 18 vs. 19; interquartile range: 14, 20). The Wilcoxon-Mann-Whitney test indicated a significant between-group difference (p = 0.0009) with a Hodges-Lehmann estimate of -4 fractions (95% confidence interval: -7 to -2). Supportive analyses used a multivariable negative binomial model (rate ratio: 0.71; p = 0.0018) and propensity score analysis (p = 0.012). The dissatisfaction rate was 20%; 78.9% of patients stated at least a little impact of trial participation on the use of health technology. Conclusions: Given the limitations of this study, the app was associated with fewer fractions with a bladder volume < 200 mL in this cohort. Although patient dissatisfaction was considered acceptable, further optimization of the app would be welcomed. Moreover, the findings of this study require confirmation in a randomized trial that also considers urinary toxicity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy and feasibility of sitting bladder volume measurement using portable ultrasound device in prostate radiotherapy.Radiological physics and technology · 2026
- Excessive Bladder Filling at Simulation Correlates with Longer Treatment Times, More Interruptions, and Inferior Patient Experiences During Prostate Cancer Radiotherapy.Practical radiation oncology · 2026
- Optimizing Patient Selection for Aquablation During the Initial Adoption Phase: Prostates Smaller Than 100 mLInternational Journal of Urology · 2026
- Adoption of Hypofractionated Radiation Therapy and Quality of Life Outcomes for Localised Prostate Cancer in an Australian Population-Based Cohort.Journal of medical imaging and radiation oncology · 2026
- Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.Cureus · 2026
- Baseline Post-Void Residual Urinary Volume Is Associated with Acute Genitourinary Toxicity After Five-Fraction Stereotactic Body Radiation Therapy for Localized Prostate Cancer.Journal of personalized medicine · 2026