Impact of Overlapping Heterogeneous Versus Homogeneous Drug-Eluting Stents on Clinical Outcomes: Should They Be Identical?
Kerim Esenboğa, Müge Akbulut, Bilge Nazar Ateş, Halil Gülyiğit, Emre Özerdem, Yakup Yunus Yamantürk, Şeyhmus Atan, Eralp Tutar
Department of Cardiology, Ankara University School of Medicine, 06230 Ankara, Türkiye.
Key points
From the paper's conclusion- Objectives: We aimed to evaluate the long-term clinical outcomes of overlapping heterogeneous drug-eluting stents (DES) in comparison to homogeneous DES.
Abstract
Background: Stent overlapping serves as a crucial strategy in achieving complete coverage of diffuse coronary artery lesions, plaque shifts, and edge dissections. Objectives: We aimed to evaluate the long-term clinical outcomes of overlapping heterogeneous drug-eluting stents (DES) in comparison to homogeneous DES. Methods: A total of 421 patients treated with overlapping DES were included in the study. The study patients were stratified into two groups according to the type of overlap: homogeneous (same antiproliferative drug and stent platform) and heterogeneous (different drug and/or platform). The primary endpoint was a device-oriented composite of cardiac death, target-vessel myocardial infarction and target lesion revascularization; a broader composite of all-cause death, any repeat revascularization, stent thrombosis, in-stent restenosis and cerebrovascular events (MACE) and its components were secondary endpoints. Propensity-score analysis with inverse probability of treatment weighting (IPTW) was used to account for treatment-selection bias. Results: The device-oriented composite endpoint occurred in 9.3% and 7.1% (p = 0.60), and MACE in 17.6% and 14.7% (p = 0.56) of patients with homogeneous and heterogeneous DES, respectively, with no significant difference in any individual component. After IPTW adjustment, heterogeneous overlap was not associated with an increased risk of MACE (odds ratio: 0.45, 95% confidence interval: 0.23-0.86) or of the device-oriented composite endpoint (0.52, 0.22-1.23). In a multivariable model with clinically prespecified covariates, lower left ventricular ejection fraction and greater total stent length, but not HbA1c, were independently associated with MACE. Conclusions: In this retrospective cohort, overlapping heterogeneous DES was not associated with an increased risk of adverse events compared with homogeneous DES, including in patients presenting with acute coronary syndromes; however, the modest sample size and the low number of events preclude conclusions of equivalence, and clinically relevant differences cannot be excluded.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long‐Term Cardiovascular Outcomes Following Percutaneous Coronary Intervention of Diffuse Coronary Artery Lesions With Overlapping Homogeneous Versus Heterogeneous Second‐Generation Drug‐Eluting StentsCatheterization and Cardiovascular Interventions · 2026
- Two-Year Clinical Outcomes of Contemporary Drug-Eluting Stents Grouped by Eluted Limus Agent: A Retrospective Cohort Study.Journal of clinical medicine · 2026
- Drug-Coated Balloon-Based Versus Drug-Eluting Stent-Only Strategy in Stable Angina and Acute Coronary Syndrome: A Propensity-Score Overlap-Weighted Analysis.Journal of clinical medicine · 2026
- Drug-coated balloon–only strategy versus drug-eluting stents in large-vessel complex PCI: a propensity-matched 3-year outcome analysisEuropean Heart Journal · 2026
- Outcomes of drug-coated balloon, crossover stenting, and ostium stenting for LAD lesions with ostial plaque continuity: an IVUS-guided comparative studyEuropean Heart Journal · 2026
- Comparison of Hybrid Strategy With Drug-Coated Balloons Versus Stent-Only Strategy for Coronary Bifurcation Lesions: A Systematic Review and Meta-Analysis.Cardiovascular therapeutics · 2026