Point-of-Care Ultrasound Use in Confirmed Acute Aortic Syndrome: A Five-Year Retrospective Cohort Study at the Ljubljana Emergency Medical Unit.
Pika Brezigar, Jan Kukavica, Borut Jug, Hugon Možina
Faculty of Medicine, University of Ljubljana, SI-1000 Ljubljana, Slovenia. · Department of Vascular Diseases, University Medical Centre Ljubljana, SI-1000 Ljubljana, Slovenia.
Key points
From the paper's conclusion- Background/Objectives: Point-of-care ultrasound (POCUS) is increasingly used in emergency care, but data on its use in acute aortic syndrome (AAS) remains limited.
Abstract
Background/Objectives: Point-of-care ultrasound (POCUS) is increasingly used in emergency care, but data on its use in acute aortic syndrome (AAS) remains limited. This single-center retrospective cohort described POCUS use among patients with confirmed AAS and explored factors associated with POCUS use and time to completion of diagnostic workup. Methods: Records coded ICD10 I71.0-I71.8 from the Emergency Medical Unit, University Medical Centre Ljubljana (2019-2023) were reviewed. Clinical, imaging, and outcome data were extracted, and diagnoses were confirmed by two investigators through manual chart review of ED documentation, radiology reports, and specialist consultation notes. Fisher's exact and Wilcoxon rank sum tests were used for comparisons. Associations with POCUS use and time to completion of diagnostic workup (defined from arrival at triage to completion of the emergency department workup) were assessed with univariable logistic regression and linear regression models, respectively. Survival was explored using univariable Cox proportional-hazards models. Statistical significance was set at p < 0.05. Results: Among 120,109 emergency department visits, 73 patients had confirmed AAS (type A: 48; type B: 17; intramural hematoma: 8). POCUS was performed in 62% of patients, more often in those who were hemodynamically unstable (87.5% vs. 54.4%; p = 0.020) or had unclear presentations (40% vs. 7%; p = 0.003). Median time to completion of diagnostic workup was shorter with POCUS (110 vs. 213 min), though not statistically significant (p = 0.069). Hemodynamic instability was associated with higher odds of POCUS use (OR 5.87, 95% CI 1.22-28.2; p = 0.028), whereas a clear clinical presentation was associated with lower odds of POCUS use (OR 0.12, 95% CI 0.02-0.55; p = 0.007). Lower triage level was associated with longer time to completion of diagnostic workup (time ratio 5.43, 95% CI 2.21-13.4; p < 0.001 for urgent vs. immediate triage), whereas very high D-dimer levels were associated with shorter time to completion of diagnostic workup (time ratio 0.44, 95% CI 0.21-0.93; p = 0.031 for highest vs. lowest quartile). In-hospital mortality was 14%, with only age associated with mortality (HR 1.06 per year, 95% CI 1.02-1.11; p = 0.007). Conclusions: In this single-center retrospective AAS cohort, POCUS was used more frequently in unstable and diagnostically unclear patients but was not associated with time to completion of diagnostic workup. Findings are descriptive and exploratory; they do not establish that POCUS accelerates diagnosis or improves outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of point-of-care ultrasound for the detection of acute aortic syndrome in the emergency department: a systematic review and meta-analysis.World journal of emergency medicine · 2026
- Point-of-care ultrasound as a frontline tool for suspected acute aortic dissection: a systematic review and meta-analysis.Quantitative imaging in medicine and surgery · 2026
- Diagnostic accuracy of point-of-care ultrasound in adult non-traumatic emergency medicine: an umbrella review.BMC medicine · 2026
- Computer tomography imaging for suspected acute aortic syndrome.Irish journal of medical science · 2026
- Accurate Differentiation of Acute Aortic Syndrome from Acute Coronary Syndrome: A Machine Learning Diagnostic Model Based on Routine Admission Variables.Journal of clinical medicine · 2026
- Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI AssessmentarXiv · 2026