Journal of clinical medicine

Rater Dependence in Emergency Department Catheter-Appropriateness Audits: A Prospective Three-Rater Study of Item-Level Reliability.

Ömer Çetin, Faruk Danış

Department of Emergency Medicine, Faculty of Medicine, Bolu Abant İzzet Baysal University, 14030 Bolu, Türkiye.

Observational · n=117

Key points

From the paper's conclusion
  • We measured how far an emergency department (ED) estimate depends on the clinician applying the checklist, and which items carry that dependence.

Abstract

Background/Objectives: Catheter-appropriateness audits report a single rate without a measure of its reliability. We measured how far an emergency department (ED) estimate depends on the clinician applying the checklist, and which items carry that dependence. Methods: We enrolled 117 consecutive adults catheterized in a tertiary ED between 21 January and 21 May 2026. Three emergency physicians independently classified every patient against a ten-item checklist drawn from the 2009 CDC/HICPAC guideline and the Ann Arbor criteria. A designated senior rater served as comparator, a clinical judgment rather than a criterion standard. We computed standalone rates, per-item Fleiss' κ and Gwet's AC1, patient-level agreement, and a post hoc counterfactual item-replacement analysis. Results: Ten patients (8.5%, 95% CI 4.7-15.0) had no valid indication according to the senior rater. Auditing alone, the two index raters would have reported 0.9% and 25.6%. Pooled agreement over 1170 patient-by-indication decisions was substantial by κ (0.630 and 0.707) and almost perfect by AC1 (0.885 and 0.925); excluding the complementary item changed neither. Patient-level agreement was lower (three-rater κ 0.199, AC1 0.792). Disagreement concentrated in hourly urine-output monitoring (AC1 0.617) and neurogenic bladder, endorsed in 44 patients by one rater and none by another (AC1 0.668). That item accounted for 48% of one rater's excess endorsements; replacing that rater's item-5 ratings with the senior rater's narrowed the between-rater range from 30-fold to 6-fold. Conclusions: In this cohort the audit rate was rater-dependent, and the dependence concentrated in identifiable checklist items. Item-level operational definitions and prospective calibration should be evaluated as strategies for improving audit reliability, and per-item agreement should be reported with a prevalence-robust coefficient alongside κ.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Rater Dependence in Emergency Department Catheter-Appropriateness Audits: A Prospective Three-Rater Study of Item-Level Reliability — Science Skim