A Multicomponent Simulation-Based Program Incorporating Ultrasound for Lumbar Puncture Training in Medical Students: A Randomized Controlled Educational Trial.
Amirah Alatawi, Hassan Moria, Talal Turki Alqubali, Fatma Toonisi, Masad Alanazi, Mishari Beragdar, Ahamed Bashaweeh, Majidah Saad Alanazi
Department of Family Medicine, University of Tabuk, Tabuk 71491, Saudi Arabia. · Department of Surgery, University of Tabuk, Tabuk 71491, Saudi Arabia.
Key points
From the paper's conclusion- The findings characterize the multicomponent UIS-LP program as delivered relative to SDL and cannot be attributed specifically to ultrasound or any other individual component.
Abstract
Background: Lumbar puncture (LP) education requires integration of anatomical knowledge, procedural skills, and safety-related decision-making. Simulation incorporating preprocedural ultrasound localization provides a structured approach to LP training; however, randomized evidence among undergraduate medical students remains limited. Methods: This single-center, parallel-group randomized controlled educational trial included 78 clinical-year medical students randomized to a multicomponent ultrasound-integrated simulation-based LP program (UIS-LP; n = 38) or self-directed learning (SDL; n = 40). The prespecified primary outcome was immediate post-intervention simulation-based LP procedural performance assessed using a 14-item Objective Structured Clinical Examination (OSCE; score range, 0-28). Secondary outcomes included procedural knowledge, ultrasound sonoanatomy identification, self-confidence, simulated vasovagal reaction management, and LP procedural performance at 2-4 weeks. Because of the observed baseline difference in procedural knowledge, the post-intervention procedural-knowledge comparison was evaluated using post hoc ANCOVA adjusted for baseline procedural knowledge. A separate post hoc ANCOVA adjusting for baseline procedural knowledge was conducted as a sensitivity analysis for the primary OSCE outcome. Secondary analyses were exploratory, with a post hoc Bonferroni sensitivity threshold of α = 0.0125. Results: Immediate OSCE scores were 24.42 ± 2.13 in the UIS-LP group and 17.29 ± 4.64 in the SDL group, with a prespecified unadjusted between-group mean difference (UIS-LP - SDL) of 7.13 points (95% CI, 5.49-8.77; Cohen's d = 1.96; p < 0.001). The post hoc ANCOVA sensitivity analysis yielded an adjusted mean difference of 8.29 points (95% CI, 6.32-10.27; p < 0.001). For procedural knowledge, the baseline-adjusted means were 7.90 for UIS-LP and 4.73 for SDL (adjusted mean difference, 3.17 points; 95% CI, 2.46-3.89; p < 0.001). Mean between-group differences were 2.97 points for ultrasound sonoanatomy identification (95% CI, 2.30-3.64), 9.89 points for self-confidence (95% CI, 7.17-12.61), and 4.24 points for simulated vasovagal reaction management (95% CI, 3.38-5.09); all four immediate exploratory secondary comparisons remained below the post hoc Bonferroni threshold. At the 2-4-week reassessment, the between-group OSCE mean difference was 7.51 points (95% CI, 6.17-8.85; Cohen's d = 2.54; p < 0.001), whereas the group × time interaction was not statistically significant (β = 0.38 points; 95% CI, -1.67 to 2.44; p = 0.714). No educational or simulation-related unintended events meeting the predefined monitoring criteria were documented. Conclusions: Immediate simulation-based LP procedural-performance scores were higher in the UIS-LP group than in the SDL group, with between-group differences also observed across the exploratory secondary outcomes. At the 2-4-week reassessment, OSCE procedural-performance scores were higher in the UIS-LP group; however, the group × time interaction was not statistically significant, and the reassessment should not be interpreted as evidence of differential skill retention. The findings characterize the multicomponent UIS-LP program as delivered relative to SDL and cannot be attributed specifically to ultrasound or any other individual component. Further studies should examine longer-term procedural performance and whether between-group differences observed in simulation are also present during appropriately supervised patient-based LP practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulation-based ultrasound-guided lumbar puncture training using a flipped classroom: a single-arm pilot programme evaluation.BMC medical education · 2026
- Development, Implementation, and Evaluation of a Structured Teaching Module for Lumbar Puncture Training Among Medical Interns.Cureus · 2026
- Improving Success Rates in Infant Lumbar Punctures: A Quality Improvement Initiative Using Ultrasound Guidance.Quality management in health care · 2026
- A prospective cohort study on ultrasound simulation training in gynecology and obstetrics using pelvic, fetometry, and breast models.BMC medical education · 2026
- Simulation-Based Assessment of Vaginal Birth Competencies in Final-Year Medical Students: A Pre–Post StudyInternational Medical Education · 2026
- 74 The use of an audio-visual method in counseling for paediatric lumbar puncture procedure. A randomized controlled trial in paediatric emergency settingsPaediatrics & Child Health · 2026