A CAP-ALT-HbA1c Model for Biopsy-Confirmed Moderate-to-Severe Hepatic Steatosis in Bariatric Surgery Candidates: Development and Internal Validation.
Jingli Ding, Mengjie Hu, He Wang, Cheng Gong, Zixuan Mei, Wanshun Chun, Dawei Deng, Zixuan Ma,
Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China. · Department of Cardiovascular Surgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China.
Key points
From the paper's conclusion- We developed and internally validated a model combining CAP, alanine aminotransferase (ALT), and glycated haemoglobin (HbA1c) to identify biopsy-confirmed S ≥ 2 steatosis in bariatric surgery candidates.
Abstract
Background/Objectives: The controlled attenuation parameter (CAP) is widely used for non-invasive assessment of hepatic steatosis, but its discrimination for moderate-to-severe steatosis may be limited in patients with obesity. We developed and internally validated a model combining CAP, alanine aminotransferase (ALT), and glycated haemoglobin (HbA1c) to identify biopsy-confirmed S ≥ 2 steatosis in bariatric surgery candidates. Methods: This retrospective single-centre study included 320 bariatric surgery candidates with preoperative CAP and laboratory data and intraoperative wedge liver biopsy as the reference standard. Candidate predictors were evaluated using univariable logistic regression, least absolute shrinkage and selection operator (LASSO) screening, and multivariable logistic regression. Model performance was assessed using receiver operating characteristic analysis, paired DeLong testing, bootstrap internal validation, calibration, Brier score, and decision curve analysis. Results: S ≥ 2 steatosis was present in 182 patients (56.9%). The combined model showed higher discrimination than CAP alone (area under the curve [AUC] 0.768, 95% CI 0.717-0.819 vs. 0.671, 95% CI 0.612-0.731), with an AUC difference of 0.096 (95% CI 0.049-0.144; paired DeLong p < 0.001). At the internally derived Youden threshold, sensitivity was 53.8% and specificity was 86.2%. The combined model also showed a lower Brier score than CAP alone (0.1941 vs. 0.2234). Bootstrap internal validation yielded an optimism-corrected AUC of 0.760 and a mean absolute calibration error of 0.017. Decision curve analysis suggested modest incremental net benefit over CAP alone. Conclusions: The CAP-ALT-HbA1c model showed higher discrimination and lower overall prediction error than CAP alone. It may complement CAP as an adjunctive tool for preoperative risk stratification, but external validation and assessment of clinically appropriate decision thresholds are required before routine clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Conventional Preoperative Prediction of MASLD-Compatible Histologic Abnormality, Fibrosis, and Higher-Grade Steatohepatitis, and Exploratory Machine-Learning Classification of MASH Severity in Patients Undergoing Roux-en-Y Gastric Bypass.Obesity surgery · 2026
- A simple clinical model for predicting multiple liver histologic injuries in obese individuals undergoing bariatric surgery.Hepatology international · 2026
- Accurate Prediction of Hepatic Disease Severity in MASLD Using a Learned PhenotypemedRxiv · 2026
- Preoperative Noninvasive Assessment for Predicting Steatosis Grade in Hepatocellular Carcinoma Patients with Chronic Hepatitis B: Comparison of Attenuation Imaging with Controlled Attenuation Parameter.Current medical imaging · 2026
- Development and validation of the HABIT score: a practical and robust tool to predict hepatic steatosis using HbA1c, BMI, and triglycerides in patients with unexplained elevated liver enzymesAnnals of Hepatology · 2026
- Hepatorenal index and an exploratory combined model for identifying moderate-to-severe histologic steatosis in patients with liver injury of undetermined etiology.Frontiers in medicine · 2026