Journal of clinical medicine

Routine Application of a Bioabsorbable Cellulose Hemostatic Agent (WoundClotTM) in Unilateral Biportal Endoscopic Lumbar Decompression: A Retrospective Comparative Study.

JinWoo Jung, Sang-Woo Lee, Donghyun Kim, Young San Ko, Dae-Chul Cho, Sang-Kyu Son, Man-Kyu Park

Department of Neurosurgery, Hu Hospital, Busan 47261, Republic of Korea. · Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.

Observational · n=115

Key points

From the paper's conclusion
  • This study evaluated the clinical necessity of routine application of a bioabsorbable cellulose-based hemostatic agent in UBE lumbar decompression.

Abstract

Objective: Unilateral biportal endoscopic (UBE) lumbar decompression is an effective minimally invasive spine surgery, but postoperative spinal epidural hematoma (PSEH) remains a practical concern. This study evaluated the clinical necessity of routine application of a bioabsorbable cellulose-based hemostatic agent in UBE lumbar decompression. Methods: This retrospective comparative study included 115 patients who underwent UBE unilateral laminectomy and bilateral decompression for lumbar spinal stenosis. Patients were divided into a control group without routine hemostatic agent application (n = 66) and a hemostatic group with routine hemostatic agent application (n = 49). Clinical outcomes, operation time, postoperative drain output, hemoglobin change, and PSEH on postoperative day (POD) 2 MRI were compared. Results: Baseline characteristics were comparable between the groups. Total drain output was significantly lower in the hemostatic group than in the control group (61.50 [50.00-78.50] mL vs. 77.00 [59.85-96.75] mL, p = 0.002), particularly on POD 2 (19.00 [11.20-22.50] mL vs. 25.00 [18.25-40.00] mL, p < 0.001). Operation time was also shorter in the hemostatic group (41.43 ± 6.69 min vs. 45.91 ± 6.32 min, p < 0.001). However, hemoglobin change, clinical outcomes, and PSEH incidence did not significantly differ between the groups. Symptomatic PSEH requiring revision surgery occurred in one control patient and in no hemostatic patients. Conclusions: Routine hemostatic agent application was not associated with a significant reduction in PSEH after UBE lumbar decompression. Although lower POD 2 drain output and shorter operative time were observed in the hemostatic group, the clinical significance of these findings remains uncertain and warrants further prospective study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Routine Application of a Bioabsorbable Cellulose Hemostatic Agent (WoundClotTM) in Unilateral Biportal Endoscopic Lumbar Decompression: A Retrospective Comparative Study — Science Skim