In Vivo Comparison of Laser Fluorescence, Near-Infrared Transillumination, and Conventional Methods for Approximal Caries Detection.
Arda Bingül, Oya Bala, Sinem Akgül, Ceyda Sarı
Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, 06510 Ankara, Türkiye. · Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Medipol University, 34083 Istanbul, Türkiye.
Key points
From the paper's conclusion- Background/Objectives: The aim of this in vivo study was to compare the diagnostic performance of conventional methods, including visual examination according to the International Caries Detection and Assessment System II (ICDAS II) and digital bite-wing radiography, with laser fluorescence (DIAGNOdent Pen) and near-infrared transillumination (DIAGNOcam and VistaCam iX-Proxi head) for the detectio
Abstract
Background/Objectives: The aim of this in vivo study was to compare the diagnostic performance of conventional methods, including visual examination according to the International Caries Detection and Assessment System II (ICDAS II) and digital bite-wing radiography, with laser fluorescence (DIAGNOdent Pen) and near-infrared transillumination (DIAGNOcam and VistaCam iX-Proxi head) for the detection of non-cavitated approximal caries and to evaluate inter-examiner agreement. Methods: A total of 76 non-cavitated posterior teeth/surfaces from patients aged 15-60 years were independently assessed by three investigators. Enamel caries validation was based on combined ICDAS II and bite-wing radiographic findings, whereas dentin caries validation was established by cavity opening and direct clinical assessment. Diagnostic performance was evaluated using sensitivity, specificity, predictive values, accuracy, and receiver operating characteristic analysis. Inter-examiner agreement was assessed using the kappa coefficient, and diagnostic performance was compared using the McNemar test (p < 0.05). Results: Sensitivity ranged from 7.5% for visual examination to 94.3% for DIAGNOdent Pen, whereas specificity ranged from 12.6% to 100.0%. Bite-wing radiography demonstrated the highest diagnostic performance (accuracy: 87.7%; AUC: 0.775), followed by DIAGNOcam (accuracy: 86.0%; AUC: 0.738) and VistaCam (accuracy: 84.2%; AUC: 0.720). Although DIAGNOdent Pen showed high sensitivity, its specificity and overall accuracy were low (31.6%; AUC: 0.535). Inter-examiner agreement was substantial for visual examination, bite-wing radiography, and DIAGNOcam, moderate for VistaCam, and slight for DIAGNOdent Pen. Conclusions: Within the limitations of this study, combining visual examination, digital bite-wing radiography, and near-infrared transillumination methods may improve the detection of approximal caries, particularly at an early stage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of quantitative light-induced fluorescence and near-infrared intraoral scanner imaging for proximal caries across predefined ICCMS radiographic thresholds: a diagnostic accuracy studyBMC Oral Health · 2026
- A critical review of the validity and reliability of caries detection methods for non-cavitated lesions.Caries research · 2026
- AI-Augmented Digital Diagnostics in Minimally Invasive Dentistry: A Case Report on Clinically Occult Approximal Caries.Healthcare (Basel, Switzerland) · 2026
- Diagnostic accuracy of intraoral scanners in caries detection: A systematic review and meta-analysis.Journal of dentistry · 2026
- Clinical assessment methods reported in randomized trials investigating dental remineralization: a scoping review with network analysisFrontiers in Oral Health · 2026
- Comparative assessment of occlusal and proximal caries detection using an intraoral scanner and panoramic radiography.BMC oral health · 2026