Predictors of Appropriate Implantable Cardioverter-Defibrillator Intervention in Adults with Congenital Heart Disease.
Jakub Malinowski, Łukasz Nowotka, Jakub Kosma Rokicki, Olgierd Woźniak, Paweł Syska, Michał Lewandowski, Artur Oręziak, Joanna Zakrzewska-Koperska,
Students' Scientific Society, National Institute of Cardiology, 04-628 Warsaw, Poland. · Department of Medical Informatics and Telemedicine, Medical University of Warsaw, 00-581 Warsaw, Poland.
Key points
From the paper's conclusion- We sought predictors of appropriate ICD intervention in this population.
Abstract
Background: Evidence to guide risk stratification after ICD implantation in adults with congenital heart disease (ACHD) is limited. We sought predictors of appropriate ICD intervention in this population. Methods: Consecutive ACHD patients implanted with an ICD (2009-2023) were analysed retrospectively. Time to first appropriate ICD intervention was modelled from a single, consistently defined start of observation. Because only 24 events were available, candidate predictors were pre-specified and each model limited to two covariates; sparse predictors used Firth penalisation, and multiplicity was addressed by the Benjamini-Hochberg false discovery rate procedure. Results: Among 56 patients (73.2% male; 22 primary and 34 secondary prevention), appropriate intervention occurred in 24 (42.9%) over a median follow-up of 51.9 months. Atrial fibrillation (HR 2.75, 95% CI 1.22-6.23) and radiographic cardiomegaly (HR 3.99, 95% CI 1.28-12.40) showed the largest unadjusted associations, whereas individual congenital lesions and disease-severity descriptors did not. No predictor remained significant after Benjamini-Hochberg correction (q ≈ 0.10). The very high hazard ratios for sparsely represented thyroid disorders (hypothyroidism, n = 2; hyperthyroidism, n = 4) were unstable under penalised estimation and are reported as exploratory. A pre-specified two-variable model (atrial fibrillation plus radiographic cardiomegaly) showed modest discrimination (optimism-corrected Harrell's C-index 0.63). Conclusions: In a heterogeneous real-world ACHD cohort, a history of atrial fibrillation and radiographic cardiomegaly were associated with appropriate ICD intervention. Given the small number of events and the sparsity of several predictors, these findings should be regarded as hypothesis-generating and require validation in larger multicentre ACHD cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wearable Cardioverter-Defibrillator in Adult Congenital Heart Disease: A Bridge to Decision, Recovery, and Advanced TherapiesHeart Failure Reviews · 2026
- Evaluation of primary prevention ICD efficacy in late elderly heart failure patients: a multicenter studyEuropean Heart Journal · 2026
- Age and triggers of inappropriate implantable cardioverter-defibrillator therapy in primary prevention patientsEuropean Heart Journal · 2026
- Head-to-head comparison of ESC 2023 and 2024 ACC/AHA primary-prevention ICD selection strategies in hypertrophic cardiomyopathy: insights from a real-world ICD-implanted cohortEuropean Heart Journal · 2026
- Strategies for preventing arrhythmic sudden death in adult congenital heart diseaseEuropean Heart Journal Supplements · 2025
- Heart failure and re-interventions in adult patients with residual right-sided congenital heart diseaseActa cardiologica. Supplementum · 2026