Temporal Patterns of Body Composition After Heart and Lung Transplantation Assessed by Bioelectrical Impedance Analysis.
Michał Bohdan, Anna Kowalczys, Alicja Radtke-Łysek, Wioletta Raczyńska, Alicja Fedyczkowska, Aleksandra Gutowska, Anna Borzyszkowska, Sławomir Żegleń,
First Department of Cardiology, Medical University of Gdańsk, Smoluchowskiego 17 Str., 80-214 Gdansk, Poland. · University Clinical Centre, Smoluchowskiego 17 Str., 80-952 Gdansk, Poland.
Key points
From the paper's conclusion- This study compared body composition parameters and their relationship with time since transplantation in HTx and LTx recipients using bioelectrical impedance analysis (BIA).
Abstract
Background/Objectives: Body composition may influence functional capacity and long-term outcomes after thoracic organ transplantation. However, direct comparisons of body composition patterns between heart transplant (HTx) and lung transplant (LTx) recipients remain limited. This study compared body composition parameters and their relationship with time since transplantation in HTx and LTx recipients using bioelectrical impedance analysis (BIA). Methods: This cross-sectional study included 79 clinically stable transplant recipients (38 HTx and 41 LTx) with a median time of 9 months after transplantation (range, 1 month-9 years). Body composition was assessed using the SECA mBCA 515 analyzer. Absolute fat mass (AFM), relative fat mass (RFM), fat-free mass (FFM), skeletal muscle mass (SMM), phase angle (PA), and extracellular water-to-total body water ratio (ECW/TBW) were measured. Associations between body composition parameters and time since transplantation were modelled using adjusted generalized additive models with separate smooth functions for HTx and LTx recipients. Results: Positive cross-sectional associations between AFM and time since transplantation were observed during the 3-9-month post-transplant interval in both groups (HTx: 0.72 kg/month, p = 0.042; LTx: 0.83 kg/month, p = 0.021). In contrast, significant positive associations between SMM and time since transplantation were observed exclusively among LTx recipients during the 1-3-month (0.59 kg/month, p = 0.039) and 3-9-month (0.49 kg/month, p = 0.003) intervals, whereas no significant associations were observed after HTx. In LTx recipients, ECW/TBW was negatively associated and PA positively associated with time since transplantation during the 3-9-month interval. Conclusions: HTx and LTx recipients exhibited different cross-sectional patterns of body composition according to time since transplantation. HTx recipients were characterized by greater adiposity without a significant association between SMM and time since transplantation, whereas LTx recipients showed positive associations between SMM and time since transplantation during the early post-transplant intervals.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physical Activity Status and Related Factors of Lung Transplant Patients Within One Year After Surgery: A Single-Center Observational Study.Canadian respiratory journal · 2026
- The application of bioelectrical impedance analysis in assessing body composition of patients undergoing cardiac rehabilitationEuropean Heart Journal · 2026
- Disentangling the effects of fluid retention and low muscle mass on bioelectrical impedance–derived indices: A stratified analysis based on body water statusClinical Nutrition ESPEN · 2026
- Asynchronous Recovery of Body Composition After Curative Surgery for Gastric and Colorectal Cancer: A Prospective Longitudinal Study.Nutrients · 2026
- A Refined Lung Transplant Frailty Scale Incorporating Serum Albumin Is Associated With Risk of Mortality in Lung Transplant CandidatesmedRxiv · 2026
- Longitudinal changes in bioelectrical impedance-derived body composition after sleeve gastrectomy in patients with class III obesity.Langenbeck's archives of surgery · 2026