Acceptance of Allogeneic Serum Eye Drops Among Users of Autologous Serum Eye Drops-A Survey-Based Study.
Frank Blaser, Mohammadjavad Abbasi, Mario D Toro, Timothy Hamann, Daniel Barthelmes, Sandrine A Zweifel, Martina M Bosch, Isabelle Meneau,
Department of Ophthalmology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland. · School of Medicine and Surgery, University of Naples Federico II, 80131 Naples, Italy.
Key points
From the paper's conclusion- Background/Objectives: To assess the acceptance of, attitudes towards, and concerns regarding allogeneic serum eye drops (Allo-SEDs) among patients treated with autologous serum eye drops (ASEDs).
Abstract
Background/Objectives: To assess the acceptance of, attitudes towards, and concerns regarding allogeneic serum eye drops (Allo-SEDs) among patients treated with autologous serum eye drops (ASEDs). Methods: We conducted this investigator-initiated, cross-sectional, single-center survey at the Department of Ophthalmology, University Hospital Zurich, Switzerland. We consecutively recruited all patients using ASEDs during routine visits, who anonymously completed a 9-item questionnaire comprising eight 11-point Likert-scale items and one open numerical item on the daily application frequency. We assessed perceived ASED effectiveness, willingness to switch to Allo-SEDs under different scenarios, and concerns regarding safety, efficacy, and immunological risks. Results: Of 202 eligible patients, 107 returned the questionnaire (53.0%). The full eligible cohort had a median (IQR) age of 63.5 (49.2-75.0) years and a median ASED treatment duration of 4.0 (1.0-8.0) years. They rated ASEDs as highly effective (median 9, IQR 8.2-10.0) and applied them a median of 7 (5-10.5) times daily. Willingness to switch was low without clinical need (median 3, IQR 0-6; p = 1.0), increased when autologous production was no longer feasible (median 7, IQR 5-9; p < 0.001), and was intermediate for general openness (median 5, IQR 2-8; p = 0.7). Concerns regarding infectious disease transmission, immunological reactions, and therapeutic efficacy correlated with lower willingness to switch (all r = -0.29 to -0.46). Daily application frequency did not correlate with acceptance. Conclusions: Patients were highly satisfied with ASEDs but were reluctant to switch to Allo-SEDs unless autologous production was no longer feasible. Among the domains assessed, concerns regarding infection, immunological reactions, and efficacy were the main barriers to acceptance, supporting targeted patient education.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Autologous Serum Eye Drops: A Systematic Review, Part I-Characteristics, Preparation, Storage, and Stability.Bioengineering (Basel, Switzerland) · 2026
- Autologous Serum Eye Drops: A Systematic Review, Part II-Clinical Application and Outcomes.Bioengineering (Basel, Switzerland) · 2026
- Efficacy and safety of 20% and 100% autologous serum eye drops in patients with severe dry eye disease: a prospective, blinded, randomized, crossover study.The ocular surface · 2026
- Long-Term Home Storage of Autologous Serum Eye Drops.Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie · 2026
- Autologous platelet-rich plasma eyedrops for severe dry eye disease unresponsive to autologous serum: A prospective single-arm interventional study.Therapeutic advances in ophthalmology · 2026
- Comparative efficacy and safety of topical therapies for ocular involvement in Sjögren's syndrome: a systematic review and network meta-analysis.Frontiers in immunology · 2026