Long-Term Follow-Up of the Reliability, Accuracy, and Morbidity of Dynamic Sentinel Lymph Node Biopsy in Patients with Intermediate- and High-Risk Penile Cancer and Clinically Negative Lymph Node Status.
Ákos Pytel, Bence Pytel, Dávid Semjén, Zsombor Ritter
Department of Urology, Medical School, University of Pécs, Munkacsy Mihaly u. 2., H-7621 Pecs, Hungary. · Department of Anatomy, Medical School, University of Pécs, Szigeti u. 12., H-7624 Pecs, Hungary.
Key points
From the paper's conclusion- Objectives: The aim of this study was to evaluate the reliability, accuracy, and morbidity of dynamic sentinel lymph node biopsy (DSNB) in patients with intermediate- and high-risk penile cancer who had clinically negative lymph nodes, with a focus on long-term follow-up outcomes.
Abstract
Objectives: The aim of this study was to evaluate the reliability, accuracy, and morbidity of dynamic sentinel lymph node biopsy (DSNB) in patients with intermediate- and high-risk penile cancer who had clinically negative lymph nodes, with a focus on long-term follow-up outcomes. Methods: Between January 2005 and January 2024, 287 patients with histologically confirmed penile cancer underwent radioisotope-guided DSNB at the Department of Urology, University of Pécs. Patients lost to follow-up within 24 months were excluded. Of the remaining patients, 211 underwent primary DSNB and 37 secondary DSNB. Thirty-nine patients in the primary DSNB group with Tis, T1a, or G1 tumours were additionally excluded, leaving 209 patients for analysis. Variables included tumour stage and grade, sentinel lymph node (SLN) yield and histology, complications, inguinal progression, false-negative rate, and radical lymphadenectomy findings. Results: A total of 573 SLNs were removed from 209 patients, with a median of 2.7 nodes per patient. SLN metastases were identified in 31 patients, involving 37 groins. Among 178 patients with negative SLNs, three developed inguinal metastases. Sensitivity was 91% per patient and 92.5% per groin, with false-negative rates of 8% and 7.5%, respectively. All false-negative cases occurred within two years, with no later inguinal recurrences. DSNB-related complications occurred in 24 patients (11.4%); most were mild or moderate and managed on an outpatient basis. Two patients required surgery and one required hospital readmission. Conclusions: In a high-volume centre, DSNB is a safe and reliable staging procedure with low morbidity in clinically node-negative intermediate- and high-risk penile cancer. Further studies should assess radiotracer injection sites and compare one-day versus two-day protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Which penile cancer patients with metastasis in a sentinel node may be spared inguinal lymph node dissection without compromising oncological safety? Development of a low-risk selection model.International urology and nephrology · 2026
- Transitioning from template-based groin dissection to dynamic sentinel node biopsy in penile cancer: Prospective validation of a standardization step.Urologic oncology · 2026
- Sentinel lymph node biopsy for nodal staging in clinically node-negative penile cancer: a 10-year cohort study.World journal of urology · 2026
- Dynamic Sentinel Lymph Node Biopsy (DSNB) in Penile Cancer: A Practical Guide for Clinical Implementation.European urology focus · 2026
- Epidemiological trends in penile cancer and the evolving role of dynamic sentinel lymph node biopsy.Urologic oncology · 2026
- Accuracy of Intraoperative Frozen Section Analysis of Sentinel Node Biopsies in Penile Cancer.Clinical genitourinary cancer · 2026