Beyond Accuracy: A Controlled Comparative Glaucoma Screening Benchmark Across Deep Learning and Hybrid Models Under Within- and Cross-Dataset Conditions.
Haifa F Alhasson, Shuaa S Alharbi, Muhammed S Alluwimi
Department of Information Technology, College of Computer, Qassim University, Buraydah 52571, Al-Qassim, Saudi Arabia. · Department of Optometry, College of Applied Medical Sciences, Qassim University, Buraydah 52571, Al-Qassim, Saudi Arabia.
Key points
From the paper's conclusion- Results: Within-dataset evaluation showed strong discrimination, with the complete hybrid CNN + histogram of oriented gradients (HOG) + local binary patterns (LBP) + minimum redundancy maximum relevance (mRMR) + RF pipeline achieving a mean accuracy of 0.8697 and an AUC of 0.8972.
Abstract
Background/Objectives: Artificial intelligence (AI) models for glaucoma screening using colour fundus photography have shown strong internal performance; however, their external validity and calibration reliability remain uncertain. This study developed a controlled four-dataset benchmark to evaluate six glaucoma-screening models across RIM-ONE, DRISHTI-GS, the Hillel Yaffe Glaucoma Dataset, and ORIGA. Methods: The evaluated models included a hybrid deep-handcrafted random forest (RF), transfer-learning and semi-supervised VGG16 models, and a compact convolutional neural network (CNN). Performance was assessed in within-dataset and cross-dataset settings using discrimination metrics, including accuracy, area under the receiver operating characteristic curve (AUC), balanced accuracy, and Matthews correlation coefficient (MCC), as well as calibration metrics, including Brier score and expected calibration error (ECE). Threshold stability, preprocessing ablation, and repeated-seed analyses were also performed. Results: Within-dataset evaluation showed strong discrimination, with the complete hybrid CNN + histogram of oriented gradients (HOG) + local binary patterns (LBP) + minimum redundancy maximum relevance (mRMR) + RF pipeline achieving a mean accuracy of 0.8697 and an AUC of 0.8972. However, cross-dataset performance was poor, with a mean accuracy of 0.5685 and an AUC of 0.5798. The denoising autoencoder-enhanced transfer-learning model showed improved probability calibration in transfer settings. Preprocessing effects were dataset-dependent, with raw images, region of interest (ROI) cropping, and Retinex normalisation producing different external performance patterns. Conclusions: High internal accuracy did not translate into reliable cross-domain generalisation. None of the evaluated models were suitable for zero-shot deployment without site-specific validation or recalibration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-Dataset Generalization of Glaucoma Detection CNNs: Effects of Operating Threshold, Multi-Source Training, and Color NormalizationarXiv · 2026
- Data-Quality-Aware Fundus Classification with Anatomy-Guided Glaucoma Assessment and Cross-Dataset EvaluationarXiv · 2026
- Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease ScreeningarXiv · 2026
- When Does Multimodal Fusion Help? Cross-Domain Transfer, Joint Fusion, and Late Fusion of SLO and OCT for Glaucoma Detection Under an Analysis-Locked EvaluationDiagnostics · 2026
- Diffusion-augmented contrastive learning for diabetic retinopathy severity classification.Frontiers in artificial intelligence · 2026
- Optimizing glaucoma detection using hybrid deep-evolutionary framework from retinal imagesMeasurement Sensors · 2026