Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty.
Thomas L Bradbury, Charlotte C Baker, Zachary M Ricciardelli, Evan Bilson, Joseph M Schwab, George N Guild
Total Joint Specialists, Northside Hospital Forsyth, Cumming, GA 30041, USA.
Key points
From the paper's conclusion- This study evaluated 90-day revision and complication rates, short-term functional recovery, and operative characteristics of a modern collared triple-tapered stem in a same-day discharge ambulatory surgery center cohort.
Abstract
Background/Objectives: Collared triple-tapered cementless femoral stems are designed to optimize metaphyseal fit, stability, and osseointegration following total hip arthroplasty (THA). This study evaluated 90-day revision and complication rates, short-term functional recovery, and operative characteristics of a modern collared triple-tapered stem in a same-day discharge ambulatory surgery center cohort. Methods: This retrospective cohort study reviewed 525 consecutive primary direct anterior THAs performed by 15 fellowship-trained arthroplasty surgeons at one group operating across several ASCs between September 2024 and August 2025. Ninety-day all-cause revision, stem-specific revision, periprosthetic fracture, and other early postoperative complications were evaluated. Kaplan-Meier estimates were used to account for variable follow-up within the 90 days. PROMs (HOOS-JR, FJS, VR-12) were collected preoperatively and at 12 weeks. Operative time was evaluated using within-surgeon analyses restricted to surgeons who used both an automated impaction device (AID) and manual impaction. Results: At a mean effective follow-up of 110 ± 39 days, the 90-day Kaplan-Meier revision-free estimate was 99.62% for all-cause revision and 99.81% for stem revision. Two patients (0.4%) underwent revision (one Vancouver B2 fracture; one infection treated with DAIR with stem retention). The early periprosthetic fracture rate was 0.2%. Five patients (1.0%) experienced dislocation, all of whom were managed with closed reduction. HOOS-JR improved by 28.7 points and FJS by 41.9 points at 12 weeks (both p < 0.0001), with 84.2% and 85.8% MCID achievement, respectively. Seven surgeons used both techniques, contributing 384 AID and 58 manual cases to the within-surgeon analysis. AID use was not associated with operative time after accounting for surgeon (adjusted difference, 0.18 min; 95% CI, -2.04 to 2.39; p = 0.8764). Conclusions: This collared, triple-tapered cementless stem was associated with low 90-day revision and complication rates and clinically meaningful short-term functional improvement in a same-day discharge ambulatory population. AID use was not associated with operative time after accounting for surgeon, although the study was not powered to compare uncommon complications between impaction methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ten-year migration analysis of a cementless metaphyseal-anchored short femoral stem in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Collared Triple Taper Stems Have Superior Biomechanical Characteristics in Compromised BoneArthroplasty Today · 2026
- Early Periprosthetic Femoral Fractures and Stem Subsidence After Direct Anterior Total Hip Arthroplasty Using a Collared, Fully Hydroxyapatite-Coated Stem.Journal of orthopaedics · 2026
- The Triple-Tapered Uncemented Femoral Stems in Slight Varus Demonstrated Excellent Early Survivorship and Clinical Results.The Journal of arthroplasty · 2026
- Collared Stems Are Associated With Reduced Early Aseptic Loosening and All-Cause Revision Rate.The Journal of arthroplasty · 2026
- Longitudinal Functional Recovery Following Primary Total Hip Arthroplasty Utilizing a Contemporary Triple-Taper Femoral Stem.Cureus · 2026