Development and Preliminary Technical Validation of an Interactive, Surgeon-Oriented Framework for Digital Surgical Occlusion Planning in Orthognathic Surgery.
Ylenia Gugliotta, Elena Carlotta Olivetti, Giorgia Bruno, Gabriele Maria Galasso, Fabio Roccia, Fabrizio Ferretti, Sandro Moos, Enrico Vezzetti,
Department of Surgical Sciences, Division of Maxillo-Facial Surgery, AOU Città della Salute e della Scienza, University of Turin, Corso Bramante 88, 10126 Torino, Italy. · Department of Management and Production Engineering (DIGEP), Polytechnic University of Turin, 10129 Torino, Italy.
Key points
From the paper's conclusion- Overall translational RMSE improved significantly (1.83 ± 0.91 to 1.09 ± 0.39 mm; p = 0.001).
Abstract
Objectives: To develop and validate a fully digital, surgeon-oriented interactive framework for final dental occlusion alignment in orthognathic patients. Methods: A digital framework integrating automatic alignment, using a two-dimensional Iterative Closest Point (2D ICP) algorithm with geometric corrections and optimization-based refinement, and an interactive graphical user interface (GUI) for standardized manual refinement were implemented in MATLAB. Validation was performed on preoperative digital models from 21 orthognathic patients. Obtained digital occlusions were compared with manually articulated physical models, considered the reference standard. Translational and rotational discrepancies were assessed before and after manual refinement. Results: Twenty-one patients were included. Manual refinement reduced the greatest translational directional bias along the Y-axis (MV: -2.26 ± 2.1 to -1.17 ± 0.92 mm) and significantly decreased the magnitude of corresponding error (MAV: 2.54 ± 1.73 to 1.26 ± 0.78 mm; p = 0.002). Error magnitude also decreased along the X-axis (1.12 ± 0.84 to 0.38 ± 0.31 mm; p = 0.002), whereas a small increase was observed along the Z-axis (0.93 to 1.21 mm; p = 0.02). Overall translational RMSE improved significantly (1.83 ± 0.91 to 1.09 ± 0.39 mm; p = 0.001). Among rotational components, yaw showed the greatest reduction in error magnitude (MAV: 2.61 ± 1.91° to 0.83 ± 0.71°; p = 0.001), while no statistically significant changes were detected for pitch (p = 0.09) or roll (p = 0.13). Rotational RMSE decreased from 2.00 ± 1.01° to 1.35 ± 0.25° (p = 0.01). Conclusions: The proposed pipeline was completed for all cases. Automatic alignment provided a reliable starting point, but standardized manual refinement remained essential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of Virtual Digital Articulation Versus Hand-Articulation Accuracy for Occlusal Registration in Orthognathic Surgery (A Randomized Clinical Trial).The Journal of craniofacial surgery · 2026
- A prototype computer-assisted system for automatic three-dimensional orthognathic surgery planning: an initial retrospective study.International journal of oral and maxillofacial surgery · 2026
- Robust cross-anatomy image registration leveraging keypoint priors and contour-based assessment.Medical & biological engineering & computing · 2026
- Accuracy of guided midface surgery in complex craniomaxillofacial anomalies.International journal of oral and maxillofacial surgery · 2026
- Virtual Occlusion Accuracy in Orthognathic Surgery: Challenges and Critical Limitations in Segmental Maxillary Planning.Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons · 2026
- Digital Diagnostics and Treatment Planning for Orthognathic SurgeryAustralian Dental Journal · 2025