Actual Hydrated Volume of Acellular Dermal Matrix in Prepectoral Breast Reconstruction.
In-Woo Chu, Jun-Ho Lee
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu 42415, Republic of Korea.
Key points
From the paper's conclusion- Background/Objectives: Acellular dermal matrix (ADM) is increasingly used in prepectoral breast reconstruction, but operative planning still relies largely on label-reported size and thickness.
Abstract
Background/Objectives: Acellular dermal matrix (ADM) is increasingly used in prepectoral breast reconstruction, but operative planning still relies largely on label-reported size and thickness. In this study, we evaluated the actual post-hydration volumetric properties of commercially available ADMs and developed manufacturer-specific reference estimates for clinical use. Methods: In this single-center retrospective study, we analyzed 200 ADM sheets used in 173 patients between February 2023 and July 2025. Standardized 20 × 20 cm2 sheets from four manufacturers were hydrated, their true volumes were measured using the water displacement method, their measured hydrated areas were recorded, and their calculated thicknesses were derived from the hydrated volume divided by the measured hydrated area. Differences based on manufacturer and thickness group were analyzed, and manufacturer-specific reference estimates for other sizes were derived and compared with independent 18 × 18 cm2 validation data. Results: In all groups, the measured hydrated volume and measured hydrate area exceeded label-reported expectations. The measured hydrated volume and calculated thickness differed significantly according to the manufacturer and thickness group, and the interaction between these factors was also significant. The measured hydrated area varied less across thickness groups, although inter-manufacturer differences were observed within the shared 1.0-2.0 mm category. Validation with independent 18 × 18 cm2 data showed overall agreement with the derived reference estimates. Conclusions: Post-hydration ADM volumetric properties differ according to manufacturer and thickness group, largely because of differences in calculated thickness rather than area alone. The proposed manufacturer-specific reference table may serve as a practical aid for volumetric planning in prepectoral breast reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of Essence Human Acellular Dermal Matrix Compared With Other Products in Prepectoral Direct-to-implant Reconstruction.Plastic and reconstructive surgery. Global open · 2026
- Comparison of DermACELL™ and Braxon® in prepectoral implant-based breast reconstruction: Complication rates and clinical implications.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- "Impact of Size of Acellular Dermal Matrix on Prevention of Capsular Contracture in Wrap-around Implant-based Breast Reconstruction".Plastic and reconstructive surgery · 2026
- The Promises and Pitfalls of Dermal Regenerative Matrices in Reconstructive Surgery: A Narrative Review.Indian journal of plastic surgery : official publication of the Association of Plastic Surgeons of India · 2026
- Plasma-Treated Acellular Dermal Matrix in Nipple Reconstruction: A Retrospective Study.Aesthetic plastic surgery · 2026
- Safety and histologic characteristics of aseptic and sterile acellular dermal matrices in irradiated implant-based breast reconstructionJournal of Plastic Reconstructive & Aesthetic Surgery · 2026