Artificial-Intelligence-Based Cephalometric Landmark Detection in Lateral Cephalograms.
Manami Yamaguchi, Masato Tsutsumi, Yasuhiro Kuroda, Yoshiki Soeda, Tetsutaro Yamaguchi
Department of Orthodontics, School of Dentistry, Kanagawa Dental University, Yokosuka 238-8580, Japan. · Life Science Center for Survival Dynamics, Tsukuba Advanced Research Alliance, 1-1-1 Tennodai, Tsukuba 305-8577, Japan.
Key points
From the paper's conclusion- This study evaluated a ResNet50-based, single-stage regression convolutional neural network for direct automatic localization of 15 landmarks on lateral cephalograms.
Abstract
Background/Objectives: Accurate landmark identification underpins reliable cephalometric analysis. This study evaluated a ResNet50-based, single-stage regression convolutional neural network for direct automatic localization of 15 landmarks on lateral cephalograms. Methods: This retrospective study included 669 lateral cephalograms (669 patients): 619 for training and 50 randomly selected for an internal holdout test set. One of five orthodontists annotated each cephalogram, and coordinates served as the reference standard. One orthodontist independently re-annotated all test images after more than 2 weeks to assess reproducibility. Model performance was evaluated using Euclidean localization errors and success detection rates (SDR). Results: Across 750 landmark predictions, mean localization error was 1.25 ± 1.39 mm (95% confidence interval, 1.15-1.35 mm) and median error was 0.72 mm. SDRs within 1.0, 2.0, and 4.0 mm were 64.5%, 81.5%, and 94.4%, respectively. A statistically significant overall difference was observed among the 15 landmarks (Friedman χ2(14) = 28.84, p = 0.011). Point A had the numerically largest mean error (1.66 mm) and the mandibular central incisor the smallest (1.04 mm). The mean difference between original and repeated annotations was 0.52 ± 0.92 mm. Conclusions: In this single-center internal holdout test set, mean localization error was below the 2.0 mm benchmark. However, 18.5% of predictions exceeded 2.0 mm, and external validity remains unconfirmed. Artificial-intelligence-generated landmarks should be verified by orthodontists, and external validation is required before broader clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of an artificial intelligence model designed for prediction of lateral cephalometric measurements from lateral photographs.BMC oral health · 2026
- Automatic Cephalometric Landmark Localization on CBCT-Derived Digitally Reconstructed Radiographs for Skeletal Malocclusion Classification.ArXiv · 2026
- Evaluating the Accuracy of an Artificial Intelligence Solution Program for Identifying Anatomical Landmarks in Orthodontics.Healthcare informatics research · 2026
- Automated cephalometric landmark detection with a dual-encoder regression network in adolescent and adult cephalograms: A retrospective diagnostic accuracy study on three public datasets.International orthodontics · 2026
- Assessment of AI-based cephalometric landmark recognition on lateral cephalometric radiographs.Frontiers in oral health · 2026
- Accuracy and reliability of 3D cephalometric landmark detection with deep learningEuropean journal of medical research · 2025