Journal of cardiovascular development and disease

Post-TAVI Hypotension as a Diagnostic and Therapeutic Challenge: A Case Report of Delayed-Onset Suicide Left Ventricle.

Martino Pepe, Ivano Barnaba, Pierpaolo Caretto, Antonio Mastrangelo, Michelearcangelo Moretti, Salvatore Giordano, Rocco Tritto, Marco Matteo Ciccone

Division of Cardiology, Department of Interdisciplinary Medicine (D.I.M.), University of Bari Aldo Moro, Piazza Giulio Cesare 11, 70124 Bari, Italy. · Division of Cardiology, Department of Medical and Surgical Sciences, "Magna Graecia" University, Viale Europa, 88100 Catanzaro, Italy.

Case report

Key points

From the paper's conclusion
  • Conclusions: Suicide left ventricle is a rare cause of post-TAVI hypotension; male sex and delayed haemodynamic instability were atypical.

Abstract

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for severe aortic stenosis leads to haemodynamic improvement. Patients with a small, hypertrophic left ventricle are predisposed to dynamic left ventricular outflow tract obstruction (LVOTO). Abrupt afterload reduction may trigger "suicide left ventricle", characterised by hypercontractility, near-complete cavity obliteration, systolic anterior motion (SAM)-related LVOTO, and hypotension. Early recognition is crucial because treatments may aggravate the obstruction. CASE PRESENTATION: A 78-year-old man with hypertension, dyslipidaemia, severe calcific tricuspid aortic stenosis, LV hypertrophy, small LV cavity, and bifascicular block underwent pre-TAVI evaluation. Coronary angiography excluded obstructive coronary disease; because of recurrent syncope, a dual-chamber pacemaker was implanted before TAVI. After transfemoral implantation of a 29 mm Medtronic Evolut FX+ bioprosthesis, the patient developed dyspnoea and hypotension. Bleeding, arrhythmias, and cardiac tamponade were excluded, and no evidence of an acute structural prosthetic complication was identified. Echocardiography showed SAM, a hyperdynamic LV with near-complete systolic cavity obliteration, and a 106 mmHg LVOT gradient with a "dagger-shaped" profile. Intravenous fluid administration, avoidance of diuretics, esmolol, and pacemaker reprogramming were followed by haemodynamic stabilisation and a reduction in LVOTO. CONCLUSIONS: Suicide left ventricle is a rare cause of post-TAVI hypotension; male sex and delayed haemodynamic instability were atypical. Early echocardiographic recognition, post-procedural monitoring, and pathophysiology-driven management were paramount for preventing progression to shock.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Post-TAVI Hypotension as a Diagnostic and Therapeutic Challenge: A Case Report of Delayed-Onset Suicide Left Ventricle — Science Skim