Mid-Term Outcomes and Echocardiographic Predictors of TTVR: Insights from the TRAVEL Study.
Xing Zhao, Hao Shi, Ying Peng, Xin Meng, Jian Yang, Yutong Jiang, Fanglin Lu, Xiaopeng Hu,
Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100037, China. · Department of Cardiovascular Surgery, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100037, China.
Key points
From the paper's conclusion- In this LuX-Valve TTVR cohort, 30-day MAEs mainly reflected perioperative or device-related complications rather than a direct signal of baseline RV dysfunction or remodeling. LuX-Valve implantation showed favorable mid-term survival and clinically meaningful procedural effectiveness; RV-centered echocardiographic markers should be considered hypothesis-generating and require validation in larger cohorts.
Abstract
BACKGROUND: The mid-term prognosis after transcatheter tricuspid valve replacement (TTVR) is poorly defined, and echocardiographic predictors remain uncertain. OBJECTIVES: To describe mid-term all-cause mortality, 30-day major adverse events (MAEs), and echocardiographic risk markers of TTVR. METHODS: Consecutive patients undergoing TRAVEL (Transcatheter right atrial-ventricular valve replacement With LuX-Valve) at three centers were retrospectively analyzed. Firth Cox regression was applied for mortality, and Firth logistic regression was used for exploratory MAE analyses. RESULTS: A total of 62 patients (median age 66.5 years [61.0-72.8], 83.8% female) were included. Over a mean follow-up of 46.2 months, seven deaths (11.2%) occurred, corresponding to mid-term survival of 88.8%. Within 30 days, 14 patients (22.6%) experienced MAEs, including three deaths (4.8%), major bleeding in eight (12.9%), surgical re-exploration in seven (11.3%), repeat open-heart tricuspid valve replacement in one (1.6%), and permanent pacemaker implantation in six (9.7%). TR was reduced to mild or less in 95.2% at 1 year. CONCLUSIONS: In this LuX-Valve TTVR cohort, 30-day MAEs mainly reflected perioperative or device-related complications rather than a direct signal of baseline RV dysfunction or remodeling. LuX-Valve implantation showed favorable mid-term survival and clinically meaningful procedural effectiveness; RV-centered echocardiographic markers should be considered hypothesis-generating and require validation in larger cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes of patients with large anatomies undergoing transcatheter tricuspid valve replacement with the LuX-Valve Plus system.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Clinical, echocardiographic outcomes and complications after transcatheter tricuspid valve replacement (TTVR): a systematic review and meta-analysisEuropean Heart Journal · 2026
- Transcatheter tricuspid valve replacement-a comparison of clinical and procedural outcomes of two different prostheses.Frontiers in cardiovascular medicine · 2026
- Early outcomes of tricuspid valve replacement in patients with tricuspid regurgitation: the Trisol Early Feasibility Study.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Acute right ventricular response to transcatheter tricuspid valve replacement.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Transcatheter Tricuspid Valve Replacement Versus Medical Therapy for Severe Secondary Tricuspid Regurgitation: The TRIPLACE Registry.JACC. Cardiovascular interventions · 2026