Key points
From the paper's conclusion- XRD confirmed high phase purity of CaHA across all measurable formulations (R, RL, H, NM); the NV pattern could not be obtained owing to its very low active-phase content (0.9% w/w), while FTIR identified a band consistent with calcium-deficient hydroxyapatite (CDHA).
Abstract
Calcium hydroxyapatite (CaHA) is widely used in aesthetic medicine for soft tissue biostimulation, yet systematic comparative data on commercial formulations remain scarce. This study aimed to characterize and compare the physicochemical properties and particle morphology of five commercially available CaHA-based dermal fillers, both in the as-received state and after in vitro incubation. Five CaHA-based fillers (coded R, RL, H, NM, NV) were analyzed using scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM/EDS), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR). Particle morphology was evaluated after 7-day incubation in phosphate-buffered saline (PBS) under simulated physiological conditions. XRD confirmed high phase purity of CaHA across all measurable formulations (R, RL, H, NM); the NV pattern could not be obtained owing to its very low active-phase content (0.9% w/w), while FTIR identified a band consistent with calcium-deficient hydroxyapatite (CDHA). The mean particle size of R, RL, H, and NM fell within 31–35 µm, whereas NV particles averaged 30 µm, contrasting with the literature-reported 8–12 µm. After 7-day PBS incubation, SEM revealed formulation-dependent morphological features: smooth microsphere surfaces with residual interparticle CMC bridging in R and RL, shell-like structures with surface microporosity in H, a distinctly microtextured surface in NM, and particle agglomeration with irregular, rough surfaces in NV. These structural and morphological differences between commercially available products may influence their mechanical stability and long-term clinical performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Morphological and Rheological Analysis of an Injectable Calcium Hydroxylapatite Dermal Filler with Lattice-Pore Surface Architecture.Journal of functional biomaterials · 2026
- Calcium Hydroxylapatite for Facial Rejuvenation: Properties, Mechanisms, and Clinical ApplicationsTissue Engineering Part B Reviews · 2026
- Integrated mechanical and structural characterisation of 24 commercial hyaluronic acid fillers: A multi-parametric framework for comparative analysisJournal of Colloid and Interface Science · 2026
- Multiscale evaluation of collagen-stimulating materials: linking physicochemical properties to dermal regeneration outcomes.NPJ Regenerative medicine · 2026
- Determination of the Properties of an Experimental Dental Composite with Addition of Hydroxyapatite with Varied Micro and Nano Particle Size: An Evaluation of Mechanical Properties, Ion Release, and Surface Characteristics.Journal of functional biomaterials · 2026
- Dilution-Driven Regulation of Biostimulatory Signaling in Calcium Hydroxylapatite-PRGF Systems: Implications for Early Dermal Remodeling.Journal of cosmetic dermatology · 2026