Comparative RP-HPTLC Lipophilicity Analysis of Bioactive 1,3,4-Thiadiazole-Resorcinol Conjugates.
Beata Paw, Marek Studziński, Sylwia Stec, Katarzyna Barańska, Irena Malinowska, Joanna Matysiak
Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego St. 4, 20-090 Lublin, Poland. · Department of Physical Chemistry, Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University, 20-031 Lublin, Poland.
Key points
From the paper's conclusion- The applicability of the HPTLC method for assessing the lipophilicity of 1,3,4-thiadiazole-resorcinol conjugates was demonstrated based on the log kw values determined by HPLC according to the OECD-recommended procedure and described previously.
Abstract
The behavior of bioactive 1,3,4-thiadiazoles of anticancer potency and cholinesterases (ChEs) inhibitors was examined by high-performance thin-layer chromatography (HPTLC) in a reversed phase (RP) system. The chromatographic systems consisted of C-18 or C-8-bonded silica as the stationary phase and binary mixtures of water with methanol, acetonitrile, acetone, or dioxane as the mobile phase. The lipophilicity parameters RMw (the RM value of a solute extrapolated to pure water as the mobile phase) were determined based on the linear relationship between compound retention and water content in the mobile phase. RMw parameters obtained from various chromatographic systems were analyzed both in relation to each other and compared with other lipophilicity parameters, including log kw values obtained by RP-18 HPLC and computationally calculated log P. Descriptive, correlation and principal component analyses were applied. The applicability of the HPTLC method for assessing the lipophilicity of 1,3,4-thiadiazole-resorcinol conjugates was demonstrated based on the log kw values determined by HPLC according to the OECD-recommended procedure and described previously. The correlation coefficients (r) between the RMw parameters for these systems and log kw (C-18) is ≥0.81, whereas for the C-8 stationary phases RMw versus log kw is ≥0.95. Taking into account the results of descriptive and correlation analysis, the C18 stationary phase with methanol as the organic modifier and the C8 stationary phase with methanol or dioxan as the organic modifier were found to be the most suitable chromatographic systems for lipophilicity determination of bioactive compounds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated chromatographic and chemometric evaluation of lipophilicity in steroidal hydrazone derivatives across multiple mobile phase systems.Journal of chromatography. A · 2026
- Theoretical and Chromatographic Studies to Determine Selected Physicochemical Parameters of 8-Trifluoromethylquinobenzothiazines as Potential Bioactive Compounds.Molecules (Basel, Switzerland) · 2026
- Enhanced selectivity in RP-HPLC-UV separation of structurally similar pentacyclic triterpenes in Centella asiatica using β-cyclodextrin as a mobile-phase additive.Journal of pharmaceutical and biomedical analysis · 2026
- Enantiomer-Resolved Biological Profiling and Chiral Developability Assessment of Novel Naphthylethyl Thioureas.Pharmaceutics · 2026
- Rethinking logP: Lipophilicity =̷ Hydrophobicity.Journal of medicinal chemistry · 2026
- Validated RP-HPLC-UV Method for the Quantification of Trans-Resveratrol in Plasma: Application to Comprehensive Stability and Comparative Pharmacokinetic StudiesACS Omega · 2026